# From sample list to plate layout, without sketching it

> Automated qPCR plate layout generation. List your samples and assays, set replicates, and Clarida generates the well annotation - Auto, Assisted, or Manual mode

Source: https://clarida.bio/blog/plate-layout-generation
Updated: 2026-03-16

[Blog](https://clarida.bio/blog)

You have 12 samples, 3 assays and triplicates. How Clarida lays out the plate for you, and which settings you can change.

By [Jan Hellemans](https://clarida.bio/blog/plate-layout-generation#about-the-authors)

March 16, 2026 2 min read

You have 12 samples, 3 assays, triplicates, and 30 minutes before you have to start your lab work. Do you sketch the layout on paper? Copy last week's Excel template and hope the columns still match? Wing it and sort out the annotation later?

I have seen both ends of the spectrum. Some researchers take shortcuts to save time, accepting that downstream traceability suffers. Others invest the effort to get proper annotation, knowing it pays off in analysis but resenting the time it takes. Neither is a good trade-off.

We built something better.

## Annotate once, use everywhere

The first part of the solution is integration. In Clarida, your qPCR plate layout is not an isolated spreadsheet. It feeds directly into lab execution. The same layout that defines your wells also generates step-by-step pipetting instructions and later carries through to properly annotated analyses.

You define your annotation once. Clarida uses it everywhere it matters.

![Step-by-step pipetting instructions generated from the plate layout, showing mix distribution and sample addition steps](https://clarida.bio/images/blog/plate-layout-pipetting-instructions.png)

## Auto · done for you

List your samples and assays, set your replicates and plate format (96-well, 384-well, or others), and there is nothing to click. Clarida produces a layout based on sensible defaults: grouping aligned with your mix configuration, vertical block orientation and adjacent replicates. For most routine experiments, this is all you need.

![Auto-generated plate layout showing a 96-well plate with color-coded assay blocks and the corresponding well annotation table](https://clarida.bio/images/blog/plate-layout-auto-design.png)

## Assisted · your preferences, our algorithm

When the defaults don't match your lab's workflow, Assisted mode lets you adjust five layout settings on 96 wells: grouping, block orientation, block style, replicate placement, and plate crossing. On 384 wells, up to two more set how the quadrants are filled. Clarida still handles all the well assignment. You stay in control of the structure without manually touching individual wells.

The settings are designed around real pipetting decisions: how your multi-channel pipet moves across the plate, whether you prefer tight rectangular blocks or gap-free continuous filling, and how replicates sit relative to each other.

![Side-by-side comparison of two Assisted mode layouts. Left: Horizontal · Rectangular, with wells grouped in rows and clear spacing between blocks. Right: Vertical · Continuous, with wells filling columns without gaps.](https://clarida.bio/images/blog/plate-layout-assisted-mode.png)

Figure 1: Left: Horizontal · Rectangular. Right: Vertical · Continuous

[Read detailed description of settings](https://clarida.bio/methods/plate-layout-algorithm)

## Manual · full control when you need it

Some experiments require exact well placement that no algorithm can anticipate. Manual mode gives you direct control over every well assignment. No generation, no constraints. You decide.

## One less thing to worry about

Proper plate annotation matters for reproducible science, but it should not cost you an hour per experiment. Whether you use the plate layout generator in Auto for routine runs or fine-tune with Assisted mode, the annotation is done in seconds and carries through your entire workflow.

[Try it in your next experiment](https://app.clarida.bio/qpcr)

## Key takeaways

- Plate annotation feeds directly into pipetting instructions and analysis - define it once, Clarida uses it everywhere.
- Auto mode lays out a sensible plate by itself, based on your mix configuration.
- Assisted mode gives you five settings, up to seven on 384 wells, to match your lab's pipetting workflow - no manual well-by-well assignment needed.
- Manual mode is always available when your experiment needs exact placement no algorithm can anticipate.
- The settings - block grouping, orientation, style, replicate placement, plate crossing and, on 384 wells, the quadrants - capture the decisions that actually matter for your workflow.

## About the author

- Jan Hellemans

  Co-founder, Clarida

  Leads the science and the methods at Clarida. Published the qBase method in 2007 and co-authored the MIQE guidelines.

  [Google Scholar](https://scholar.google.com/citations?user=L8EeDgwAAAAJ)

## Your next plate, laid out for you.

The layout approach in this post is built into Clarida. Start a free experiment and let it lay out your plate. No install, export anytime.

[Start free](https://app.clarida.bio/login) · [Read the method](https://clarida.bio/methods/plate-layout-algorithm)
