# 2026.6 · Trust your numbers

> Sample and assay QC, inter-run calibration, global mean normalization, eight statistical tests and saved analyses. The first paid plans arrive too.

Source: https://clarida.bio/changelog/2026-6
Updated: 2026-06-09

[Release notes](https://clarida.bio/changelog)

Sample and assay QC, inter-run calibration, global mean normalization, eight statistical tests and saved analyses. The first paid plans arrive too.

By [Jan Hellemans](https://clarida.bio/changelog/2026-6#about-the-authors)

June 9, 2026 Updated June 18, 2026 8 min read

In April we introduced the qPCR analysis pipeline for relative quantification. May brought your qbase+ experiments into Clarida. June adds the quality controls and calibration a multi-run experiment needs before you trust its numbers. You can now scan your samples and assays for outliers and failed controls at a glance, calibrate quantities across plates so multi-run experiments are actually comparable, normalize large panels without picking reference genes, run confirmatory statistical tests, and save any exploration as an annotated, frozen record.

The first paid plans arrive too: a lab can choose one in Settings, without writing to us.

Go explore. Do analyze.
Jan

## New features

### Comparable quantities across plates

In experiments with individual assays spread across plates, technical artifacts could introduce run-specific biases that affect reliable comparison of samples between runs. Clarida now removes that offset automatically with inter-run calibration: for a given assay, any biological sample you happen to place on more than one plate becomes an inter-run calibrator used to correct for any run-specific bias detected.

![Inter-run calibration view inside Cq processing: a target × run matrix showing the calibration factor and its standard error applied to each run, color-coded from negative (blue) to positive (red) shifts, with an IRC QC strip plot above and a details panel listing per-run factors with OK and Flagged status](https://clarida.bio/changelog/media/2026-6-inter-run-calibration.png)

The calibration algorithm uses an ordinary least squares fit to convert Cq values into calibrated Cq values in a way that is independent of the experiment design or the order in which runs are combined. Any run that cannot be calibrated for lack of inter-run calibrators is given a calibration factor of zero, assuming no run-specific bias and applying no correction at all. An assay-run matrix shows you the calibration factor applied and its standard error, turning calibration into a quality check: a large factor or error points straight at a problem run, and disconnected runs are surfaced explicitly rather than silently producing wrong numbers.

In Clarida there is no need to manually define inter-run calibrators or to name a sample differently in each run. Just use a single, unique name for any biological sample across your entire experiment. If individual assays are spread across runs, any sample measured for that assay in multiple runs will automatically be used for inter-run calibration. Clarida's inter-run calibration also accepts almost any experiment design.

### Normalize large panels to the global mean

For whole-miRNome and other large unbiased panels, picking a fixed set of reference genes is often unreliable or simply impractical. Clarida now offers Global Mean normalization as a third method alongside None and Reference Genes, normalizing to the geometric mean of all detected targets following the [D'haene et al. 2012](https://pubmed.ncbi.nlm.nih.gov/22144205/) framework.

![Normalization section set to Global Mean: a table of candidate miRNA targets (hsa-mir-659, hsa-miR-569, and others) ranked by stability with their mean Cq, percent detected, and SD of log2(NRQ), forming a 5-target candidate panel, above a per-sample normalization-factor bar chart with the NF = 1.0 reference line](https://clarida.bio/changelog/media/2026-6-global-mean.png)

The same table that evaluates your normalization doubles as a follow-up planning tool: it surfaces the most stable targets so you can pick a small panel of surrogate reference genes to validate in a smaller downstream study. A "common" variant restricts the calculation to targets detected in every sample, so variable dropouts don't bias the result.

### Sample and assay QC at a glance

A new QC section sits between Cq processing and Exploration and gives you a fast, scannable read on data quality. Outlier samples and assays stand out on normalization factor, average Cq, detection fraction, and replicate count. Positive and negative controls are checked against their expected ranges in the same view.

![Sample & Assay QC section: two blocks of horizontal dot-plot strips, Sample QC rows for NF, average Cq, detection fraction, replicate count, and controls, and a parallel Assay QC block, with OK and issue zones shading; below, a detail bar chart of normalization factor per sample with three outliers highlighted in red](https://clarida.bio/changelog/media/2026-6-sample-assay-qc.png)

All quality metrics are summarized as a list of horizontal dot-plot strips with OK and issue zones, so distribution outliers and control failures stand out. Sample QC flags problem samples, and a matching QC covers each assay, so failed targets and contamination are as easy to catch as problem samples. Click on any of the dot plots for a bar chart view with details at the sample or assay level.

### Save and revisit your explorations

For the sake of scientific rigor, and to minimize HARKing or p-hacking, we clearly separated data exploration from statistics. Where data exploration used to be limited to a single bar chart, Clarida now adds correlation analyses: gene to gene, and NRQ values against a numeric sample property like dose, age, or optical density.

Any exploration that reveals something of relevance, whether good (a potential signal for upregulated expression) or bad (a technical artifact), can now be saved. Stored analyses are not merely screenshots but actual snapshots, including all data and settings from the time of recording. This lets you build a list of recorded findings that is unaffected by any changes you might still make to the experiment.

![Exploration section with a Saved explorations list showing two named, typed entries (a Gene–gene 'Reference gene correlation plot' and an NRQ bar 'Differential expression for Palm') each with an Open button, above a live NRQ bar chart configured by target, grouping, scale, and ordering, ready to save](https://clarida.bio/changelog/media/2026-6-stored-analysis.png)

You can annotate a stored analysis as a whole, as well as a selection of individual datapoints. Specific datapoints can be marked in color or with alternative symbols, each with a corresponding note attached like a legend, so a saved analysis carries its own visual commentary. When you want to iterate, create an editable copy, recorded against the original, leaving the first record intact.

![A saved NRQ bar chart grouped into 'No' and 'Yes' treatment groups, with Sample05 highlighted in pink, and an Annotations panel below carrying a general note ('Treatment appears to result in downregulation of Palm') plus a per-point note attached to Sample05 ('one deviating, low-quality measurement')](https://clarida.bio/changelog/media/2026-6-exploration-highlights.png)

### Eight tests, each saved with its result

The Statistics section now hosts eight formal tests: Welch's and Student's t-tests, the paired t-test, the Wilcoxon signed-rank and Mann-Whitney U non-parametric alternatives, one-way ANOVA with post-hoc comparisons, and Pearson / Spearman correlations across multiple gene pairs with per-pair confidence intervals and multi-testing correction.

![Setting up a Welch's t-test (unpaired): a test picker plus a settings form for target Palm, grouping column Treatment, the two compared groups (No vs Yes), alpha 0.05, and a one-sided direction (No > Yes), with an Analyze button to compute and save in one step](https://clarida.bio/changelog/media/2026-6-setting-up-statistics.png)

Tests are click-to-compute by design: you pick a test, set it up, and click Analyze to compute and save the result in one step. Unlike explorations, there is no live view recomputing as you tweak settings, which guards against accidental p-hacking. And like explorations, statistical analyses are stored in a list of results, ready for reinspection or reporting.

![A saved Welch's t-test result, 'Test for reduced Palm expression', showing the settings summary and an outcome table (t = 7.631, df = 8.8, p = 1.80e-5, geomeans 1.90 vs 0.53, ratio 3.59), above a two-bar chart of the No and Yes groups with 95% confidence intervals, plus a Create editable copy action](https://clarida.bio/changelog/media/2026-6-inspecting-statistics.png)

## Quality of life

- **Results follow upstream changes** · A new recalculation coordinator updates downstream results after each upstream change, and skips recomputation that is not needed when you reopen an experiment.
- **Fullscreen workflow sections** · Section navigation was rebuilt to support a fullscreen wizard mode, so you can focus on one workflow step at a time without the surrounding context as a distraction.
- **Soft-delete for experiments** · Experiments can now be deleted from the experiment overview via the three-dot menu. Deleting an experiment now hides it instead of erasing it.
- **Inline run renaming** · Rename a run directly in Annotation review and the new name propagates live across the workflow. Short names keep the inter-run calibration view readable where long generated ones would crowd it.
- **Clear processing feedback** · Workflow sections now show a spinner while they recompute, so you always know when results are still settling.
- **Process larger experiments** · The cap of 1000 rows per request is raised to 50,000, so larger experiments are read in full. See Changes that may affect you below.
- **Rescale to group** · The result scaling options have been expanded to include scaling to a group, e.g. setting the average pre-treatment levels to one to help interpretation of the post-treatment values.
- **Clearer chart axes** · The y-axis on the expression and normalization charts now picks readable, evenly spaced values on linear and log scales, even when your data spans a very wide or very narrow range. Labels no longer crowd together or collapse to a single one.

## Plans and billing

Clarida now has paid plans you can set up yourself, right from Settings → Billing. No sales email required to get past the free tier.

- **Pay-as-you-go credits** · Buy experiment credits via Stripe Checkout and run experiments paid from a shared per-organization balance, with optional auto-recharge, so running out does not stop you mid-experiment.
- **Lab subscriptions** · Choose a Lab (Academic) or Lab (Commercial) subscription with the included experiment volume that fits your group. Billing is monthly or yearly, and the quota resets each period.
- **One pricing surface, everywhere** · The same pricing calculator you see on the website now lives inside the app, wired to authenticated checkout, and the billing page reads the same way whether you are on Free, pay-as-you-go, or subscribed.

The free tier still includes the same functionality and allowance provided to individual researchers.

## Patch 2026.6.1

June 18, 2026

### Import and annotation in one section

Getting instrument data into an experiment used to span two separate sections, "Import data" and "Annotation review", which was confusing, especially when it did not apply. 2026.6.1 merges them into a single, progressive **Import & annotate** section with three explicit steps: import your files, link each imported run to the right run in your design, and reconcile anything that needs a decision. You can see at a glance what was detected, what still needs your attention, and what is already done.

![The Import & annotate section at its Link step, with Import done and Reconcile still to come: three imported CSV files awaiting linking and three designed runs awaiting data, the Run menu open on Run 1, Run 2, Run 3 and Promote to new run, and a Promote all unlinked (3) button](https://clarida.bio/changelog/media/2026-6-1-import-annotate.png)

The rework also fixes a set of import bugs and surprises, so bringing data in behaves the same way every time, with nothing happening silently behind the scenes.

For a full account of what the importer reads and how the one-to-three import steps adapt to your experiment, see [Importing instrument data](https://clarida.bio/methods/importing-instrument-data) in our methods library.

### Quality of life

- **A clearer first run** · New accounts now land on a focused starting page with demo experiments you can open right away and an unambiguous choice between bringing your own data and exploring an example.
- **Reference gene finder** · The free Reference gene finder now allows you to exclude specific samples or genes directly in a grid before running geNorm, so removing bad data no longer means editing it outside the tool.
- **Deleted runs can be restored** · Deleting a whole run now snapshots its design first, so the action is recoverable, and restoring a snapshot writes data back correctly.
- **Footer navigation** · The qPCR footer subsection row now shows correctly when a main section is active.

## Changes that may affect you

Some results change. What to re-check is below.

**Inter-run calibration is on by default for new experiments.** When the same biological sample is measured for a given assay on more than one plate, new experiments now produce calibrated quantities (CNRQ) automatically, removing per-plate technical offsets. Before, CNRQ equaled NRQ whatever the plate layout. You can turn inter-run calibration off if you prefer to keep working with uncalibrated data.

**Existing experiments are unchanged.** Inter-run calibration defaults to *off* for experiments created before this release, so your historical CNRQ values are numerically identical to what they were. You can enable calibration per experiment from the analysis settings and recompute when you are ready.

**Migration:** No action needed. To apply calibration to an older multi-plate experiment, toggle inter-run calibration on in its analysis settings and the quantification pipeline will recompute.

Added on October 30, 2026: changes we left out at release.

**Experiments with more than 1000 rows were cut off.** Before 2026.6, Clarida read at most 1000 rows per request, so the measurements beyond them were silently left out and results for larger experiments were calculated on part of the data. The cap is now 50,000 rows. Re-open a large experiment analyzed before this release and check its results.

## About the author

- Jan Hellemans

  Co-founder, Clarida

  Leads the science and the methods at Clarida. Published the qBase method in 2007 and co-authored the MIQE guidelines.

  [Google Scholar](https://scholar.google.com/citations?user=L8EeDgwAAAAJ)

## Save the exploration that showed it.

A saved exploration keeps the data and settings of the moment you saved it, with your notes on the points that matter.

[Start free](https://app.clarida.bio/login) · [How saved explorations work](https://clarida.bio/methods/exploration-and-stored-analyses)