# Should your bio-IT team build the qPCR analysis?

> Building qPCR analysis into LabWare, Sapio and other ELNs and LIMS, compared with Clarida beside them: what each does best, every fact dated and linked.

Source: https://clarida.bio/compare/eln-lims
Updated: 2026-11-10

[Compared with your ELN or LIMS](https://clarida.bio/compare)

A bio-IT team can program qPCR into your LIMS. Clarida brings the plate rules and the methods ready-made, and files carry the results back.

[Start free](https://app.clarida.bio/login) · [Side by side](https://clarida.bio/compare/eln-lims#side-by-side)

4 [experiments](https://clarida.bio/pricing#whats-an-experiment) in your first month, then 2 a month. No card.

> **experiments**: The runs and analysis behind one scientific question. Counted once, when you create it. Re-analyzing, reporting and exporting are free, with no limit on samples, assays or runs. [How pricing counts experiments](https://clarida.bio/pricing#whats-an-experiment)

- **You keep**: Samples, signatures, the release
- **You add**: qPCR methods your team doesn’t code

## When is your ELN or LIMS the better home?

Platforms that combine both, like [Labguru](https://www.labguru.com/) and Revvity’s [Signals Notebook](https://assets.revvitysignals.com/m/1818c814decad2d2/original/Signals-Notebook-Data-Sheet.pdf), count here too; Benchling has [its own page](https://clarida.bio/compare/benchling).

- **Your samples, stock and requests live there**: Every result lands beside them: LabWare tracks specimens [end to end](https://www.labware.com/industries/healthcare)
- **Your protocols are versioned there**: SciNote keeps [a version history](https://knowledgebase.scinote.net/en/knowledge/how-to-save-different-versions-of-a-protocol) its owner publishes; eLabFTW starts from [a template](https://doc.elabftw.net/docs/usage/user-guide/templates)
- **A liquid handler fills your plates**: In Sapio’s [LabCorp setup](https://www.sapiosciences.com/resource/optimizing-clinical-diagnostic-lab-workflows-for-labcorp/), the LIMS builds the plates, robot instructions and worklists
- **Your lab needs signatures and audit trails**: [LabWare](https://www.labware.com/lims) has both as standard; SampleManager asks for [a reason at each change](https://www.thermofisher.com/order/catalog/product/INF-11000/faqs)
- **The assay is a fixed test with a release step**: Diagnostic labs run qPCR this way: Sapio lists qPCR and dPCR among the algorithms its LIMS runs at LabCorp
- **Your bio-IT team codes in the platform**: [LIMS Basic](https://www.labware.com/labwaretraining), Sapio’s [Python library](https://pypi.org/project/sapiopylib/), Labguru’s [code blocks](https://www.labguru.com/automation) or LabArchives’ [custom widgets](https://www.labarchives.com/blog/discover-the-labarchives-widget-manager-and-library-a-new-era-of-eln)
- **Data from every cycler must flow into one system**: Benchling connects [over 200 instruments](https://www.benchling.com/automation), Dotmatics Luma [more than 100](https://www.dotmatics.com/luma/eln-integration)
- **You want a free notebook you host**: [eLabFTW](https://www.elabftw.net/): open source, with no features behind a paywall

## Does your LIMS team now maintain qPCR code?

- **If the analysis is one person’s code,** whoever inherits it has to learn it before changing anything.
- **Every platform upgrade means a code review.** LabWare consultants advise [reviewing LIMS Basic code at each new version](https://clarkstonconsulting.com/insights/adhering-to-lims-basic-coding-standards/), and Sapio’s Python library has to [match the platform version](https://pypi.org/project/sapiopylib/).
- **The method stopped at ΔΔCq.** [MIQE 2.0](https://doi.org/10.1093/clinchem/hvaf043) recommends against relying on it, and efficiency per target, several reference genes and error carried to the result are code someone has to write, test and keep.
- **The code needs assessing for as long as it lives.** EU GMP Annex 11 asks custom software for formal assessment over “all the life-cycle stages of the system” ([§4.6](https://health.ec.europa.eu/system/files/2016-11/annex11_01-2011_en_0.pdf)), and puts each edit through change control.
- **The first result can be a year away.** A LIMS implementation takes [from a couple of months to a year or more](https://www.csolsinc.com/resources/how-long-does-a-lims-implementation-take), says the consultancy CSols, and more customization means longer testing.
- **If the Cq values go to Excel for analysis,** the LIMS only stores them.

## Side by side

| What you need | Built in your ELN or LIMS | Clarida |
| --- | --- | --- |
| Define |  |  |
| Protocols and the plan | Stronger: **Versioned protocols** Protocol templates [with a version history](https://knowledgebase.scinote.net/en/knowledge/how-to-save-different-versions-of-a-protocol), published by their owner; [experiment templates](https://doc.elabftw.net/docs/usage/user-guide/templates) for what you often run | **Goal and preset** Background, goal and linked papers; a preset brings the settings set and the steps |
| Design |  |  |
| Samples, stock and requests | Stronger: **System of record** Samples, stock and requests [tracked end to end](https://www.labware.com/industries/healthcare), linked to every result | **qPCR only** Samples and assays per experiment and in a shared library, with their source positions |
| The plate layout | **Plates, worklists** Plate builds, robot instructions and [worklists](https://www.sapiosciences.com/resource/optimizing-clinical-diagnostic-lab-workflows-for-labcorp/), configured for your workflow | **Laid out for you** From your grouping and fill rules, replicates side by side for a multichannel pipette, the reason shown |
| Execute |  |  |
| Mixes and volumes | **Yours to build** A form or [calculator widget](https://www.labarchives.com/blog/discover-the-labarchives-widget-manager-and-library-a-new-era-of-eln) someone writes and keeps up | Stronger: **Worked out** Every mix per reaction and in total, surplus included, recomputed when the design changes, until the runs are ready |
| Import |  |  |
| qPCR run files | **Via a parser** Connectors such as [Luma](https://www.dotmatics.com/luma/eln-integration) and [LabStation](https://www.labware.com/industries/healthcare) read instrument output; the curves depend on the parser | Stronger: **Read natively** CFX, QuantStudio, LightCycler 480, Rotor-Gene and RDML files with raw curves, matched to your plate |
| Analyze |  |  |
| qPCR methods | **Yours to write** In the platform’s own code: [LIMS Basic](https://www.labware.com/labwaretraining), [Python](https://pypi.org/project/sapiopylib/) or [code blocks](https://www.labguru.com/automation) | Stronger: **Built in** Efficiency per target, several reference genes with geNorm and NormFinder, error carried to the result |
| Checking the math | **Your tests** Custom code needs [a life-cycle validation process](https://health.ec.europa.eu/system/files/2016-11/annex11_01-2011_en_0.pdf) that your team runs | Stronger: **Published, tested** Built on the published qBase model; NormFinder checked against its authors’ Excel add-in, geNorm’s M values match qbase+ |
| Report |  |  |
| The result on record | **Beside the sample** Stored with the sample it came from; [reports built in the LIMS](https://www.sapiosciences.com/resource/optimizing-clinical-diagnostic-lab-workflows-for-labcorp/) | **Report, Excel, RDML** A PDF or HTML report; the whole experiment written into your Excel notebook; RDML with the raw curves |
| Throughout |  |  |
| Audit trail and signatures | Stronger: **Part 11 features** [LabWare](https://www.labware.com/lims) has signatures and audit trails as standard; SampleManager keeps [old and new values, with a reason](https://www.thermofisher.com/order/catalog/product/INF-11000/faqs); [SciNote](https://www.scinote.net/product/scinote-in-regulated-environments/) offers a Part 11 add-on | **Decisions stored** Setting changes, automatic exclusions and accepted QC deviations, with who and when; no e-signatures |
| After a software update | **Code to recheck** Custom code is [reviewed at each upgrade](https://clarkstonconsulting.com/insights/adhering-to-lims-basic-coding-standards/); add-on libraries [match the platform version](https://pypi.org/project/sapiopylib/) | Stronger: **Maintained for you** Methods kept current by Clarida; a saved analysis never changes after an update |
| Changing a method | **Change control** Through your change process and user roles, then revalidation | **Versioned settings** Named settings sets freeze once used; each experiment keeps its own copy; owner, admin and member roles |
| Connecting the rest of the lab | Stronger: **APIs, connectors** Benchling lists [over 200 instruments](https://www.benchling.com/automation); APIs such as [eLabFTW’s](https://doc.elabftw.net/) serve scripts and integrations | **Files** Excel, CSV and RDML in; Excel, RDML and a PDF report out (each table as CSV); no public API |
| First result | **A project** An implementation takes [months to a year or more](https://www.csolsinc.com/resources/how-long-does-a-lims-implementation-take), then the qPCR code | Stronger: **No project** Start free and import a run file; nothing to install |

marks the stronger tool for that need.

### In short

- **Stronger in your ELN or LIMS**: Protocols and the plan · Samples, stock and requests · Audit trail and signatures · Connecting the rest of the lab
- **Stronger in Clarida**: Mixes and volumes · qPCR run files · qPCR methods · Checking the math · After a software update · First result
- **A draw**: The plate layout · The result on record · Changing a method

## How do you check it on one run?

- **Export one finished run and its sample list.** From the instrument and the LIMS, as files; nothing gets connected.
- **Put the workbook beside the LIMS record.** It holds the plan, the data, the settings and the results.
- **Ask your QA what they would need to see.** The settings it started from, the stored decisions and the frozen analysis are what Clarida can show.

## What stays in your LIMS, and what moves?

- **Keep in your LIMS**: Samples, stock, signatures and the release, beside every result
- **Keep in your ELN**: The protocol; Clarida writes the experiment into your lab’s [Excel notebook](https://clarida.bio/qpcr/define#notebook) once you attach it
- **Bring to Clarida**: Sample and assay lists as Excel, CSV or text, [into Design](https://clarida.bio/qpcr/design#sample-prep) with their source positions, then the run file
- **Work as a team**: Owner, admin and member roles in one workspace, on a paid plan; colleagues can join by their email domain
- **What does not connect**: No direct link to an ELN or LIMS and no public API: files carry the data both ways ([RDML](https://clarida.bio/qpcr/report#export-rdml), Excel, a PDF report)

## Frequently asked questions

### Could your bio-IT team build this instead?

Yes, it could. Much of the effort comes after the first version: plate layout rules and mix volumes, efficiency per target, several reference genes and error propagation, each tested, rechecked after every platform upgrade, and kept alive when its author leaves. In Clarida that work is done and kept up by us, which leaves your team’s time for the integrations specific to your lab.

### What does Clarida add if your LIMS already makes plates and worklists?

For a liquid handler, keep the LIMS worklist: Clarida writes none. Where plates are filled by hand, Clarida lays them out by qPCR rules (grouped by assay or sample, replicates side by side for a multichannel pipette), works out every mix with its surplus and guides the filling, one stage at a time. Notes left on a well come back beside its measurement when you analyze, and the run file is matched to the plate you filled.

### Does Clarida have electronic signatures?

No. That is a row your LIMS wins. Clarida stores each setting change, each automatic exclusion and each accepted QC deviation with who and when, keeps imported data unchanged, and freezes saved analyses. A LIMS with Part 11 features does not settle compliance by itself either: [eLabFTW’s documentation](https://doc.elabftw.net/) says of its own ELN that it depends on how the system is configured, validated and used.

### Can Clarida release a pass or fail result?

No. Clarida [calls each sample per target](https://clarida.bio/qpcr/detection), from a cut-off you set per assay, for research use; the release decision stays in your LIMS.

### What does a first try cost beside your LIMS?

Nothing, and no system gets connected. Clarida’s free plan: 4 experiments in your first month, then 2 a month. No card.

## Sources

Each source with the day we last checked it. Something out of date? [Tell us](https://clarida.bio/talk-to-us?topic=help).

- [Labguru (home page)](https://www.labguru.com/) One platform with a notebook, a LIMS and inventory Checked October 27, 2026
- [Revvity, Signals Notebook data sheet](https://assets.revvitysignals.com/m/1818c814decad2d2/original/Signals-Notebook-Data-Sheet.pdf) A cloud-native electronic lab notebook Checked October 27, 2026
- [Bustin et al. (2025), MIQE 2.0, Clinical Chemistry 71:634](https://doi.org/10.1093/clinchem/hvaf043) Against relying on ΔΔCq; efficiency-corrected quantities; reference genes shown to be stable Checked October 26, 2026
- [European Commission, EU GMP Annex 11, computerized systems (2011)](https://health.ec.europa.eu/system/files/2016-11/annex11_01-2011_en_0.pdf) Custom systems need formal assessment across every life-cycle stage; change control; e-signatures Checked October 26, 2026
- [CSols, how long a LIMS implementation takes](https://www.csolsinc.com/resources/how-long-does-a-lims-implementation-take) From a couple of months to a year or more; more customization, more testing Checked October 26, 2026
- [LabWare, LIMS overview](https://www.labware.com/lims) Electronic signatures, access controls and audit trails as standard Checked October 29, 2026
- [LabWare, laboratory automation for public health and clinical diagnostics](https://www.labware.com/industries/healthcare) Instrument output parsed into the LIMS; plate management, worklists, liquid handlers Checked November 10, 2026
- [LabWare, training: configuration using LIMS Basic](https://www.labware.com/labwaretraining) LIMS Basic, the platform’s own language Checked October 26, 2026
- [Clarkston Consulting, LIMS Basic coding standards](https://clarkstonconsulting.com/insights/adhering-to-lims-basic-coding-standards/) LIMS Basic code reviewed for high-impact changes and at each version upgrade Checked October 26, 2026
- [Thermo Fisher, SampleManager LIMS FAQ](https://www.thermofisher.com/order/catalog/product/INF-11000/faqs) Audit events with old and new value, who and when; a reason asked at each change Checked October 26, 2026
- [Sapio Sciences, LabCorp case study](https://www.sapiosciences.com/resource/optimizing-clinical-diagnostic-lab-workflows-for-labcorp/) qPCR and dPCR algorithms; plates, robot instructions and worklists built in the LIMS Checked October 26, 2026
- [PyPI, sapiopylib](https://pypi.org/project/sapiopylib/) Sapio’s Python library and webhooks; its version must match the platform’s Checked October 26, 2026
- [SciNote knowledge base, protocol versions](https://knowledgebase.scinote.net/en/knowledge/how-to-save-different-versions-of-a-protocol) Protocol templates keep a version history; only their owner publishes a new one Checked October 26, 2026
- [SciNote, SciNote in regulated environments](https://www.scinote.net/product/scinote-in-regulated-environments/) A 21 CFR Part 11 add-on: electronic signatures, witnessing, audit trails Checked October 26, 2026
- [eLabFTW (home page)](https://www.elabftw.net/) Free and open source (AGPLv3), with no features behind a paywall Checked October 29, 2026
- [eLabFTW documentation, FAQ](https://doc.elabftw.net/) Compliance “depends on how the system is configured, validated, and used”; an API for scripts Checked November 10, 2026
- [eLabFTW documentation, templates](https://doc.elabftw.net/docs/usage/user-guide/templates) Templates as the skeleton of an experiment you often run Checked October 26, 2026
- [Benchling, automation](https://www.benchling.com/automation) Over 200 instruments supported, qPCR systems among them Checked October 29, 2026
- [Dotmatics, Luma Lab Connect and the ELN](https://www.dotmatics.com/luma/eln-integration) Over 100 instruments with ready-made parsers, results written into ELN experiments Checked October 26, 2026
- [Labguru, automation](https://www.labguru.com/automation) Custom code blocks in Python, Ruby and C# Checked October 26, 2026
- [LabArchives, the widget manager and library](https://www.labarchives.com/blog/discover-the-labarchives-widget-manager-and-library-a-new-era-of-eln) Professional and Enterprise users build custom widgets: forms, calculators, applications Checked October 26, 2026

Checked November 10, 2026

## No integration project before the first result.

Import a run file, then save the Excel workbook to your ELN. Your LIMS stays as it is. 4 experiments in your first month, then 2 a month. No card.

[Start free](https://app.clarida.bio/login) · [Talk to a founder](https://clarida.bio/talk-to-us?topic=demo)