# Your customers start from the cycling and settings you validated

> Publish your qPCR master mix with its cycling protocol and analysis settings as a preset your customers start from. Set up with you in a pilot.

Source: https://clarida.bio/partners/reagent-makers
Updated: 2026-11-09

[For master mix makers](https://clarida.bio/partners)

Your mix becomes a preset with its cycling protocol and analysis settings, and each experiment on it starts from them, on the lab’s own instrument.

A partnership, set up with you

[Plan a pilot](https://clarida.bio/talk-to-us?topic=pilot)

## What your customers start from

When a researcher runs your mix from its preset, the analysis begins from your recommendations rather than a blank page.

**Your recommended settings.** The preset starts each customer's experiment from your mix, your cycling protocol and the analysis settings you validated on. Every customer reads your mix from the same defaults, whichever instrument they run, and can still change them for their own run. Your mix keeps your name in the experiment while it is unchanged.

**A standard curve on their own instrument.** A lab that wants to check your mix on its own instrument runs a dilution series, and Clarida reports efficiency, R² and replicate spread before it commits samples.

**A record of each run.** Every analysis keeps the settings it used and the Cq calling behind it, and exports as RDML or an Excel workbook, so it can be reopened months later when a reviewer asks.

## Can you see how your mix runs in labs?

Your master mix runs inside other people's assays, on instruments you never see. A view of how it holds up there isn't built. Your datasheet reports efficiency, R² and replicate spread from your own validation runs. What a view across labs would add to them is on [the field view page](https://clarida.bio/partners/field-view).

What a view of your mix would follow is a question for the pilot: a new lot reading unlike the one before it, or one class of instrument reading apart from the others. Following a lot needs its number, which Clarida does not record today.

## Frequently asked questions

### Is there a fit for a master mix?

Yes, in a different shape from a kit. A kit defines a readout: targets, thresholds, a call rule, which a customer [starts from as a preset](https://clarida.bio/partners/kit-makers). A master mix defines a chemistry, and the customer brings their own assays and samples to it, so there is no single readout to pre-build. What fits a mix today is your settings as a preset ([presets](https://clarida.bio/methods/presets)).

### Does Clarida read your customers' run files?

Clarida reads run files from CFX, LightCycler 480, QuantStudio, Rotor-Gene or RDML, with their amplification curves, and a Cq table from any instrument. SYBR Green and probe chemistries come in, singleplex and multiplex. Where Clarida calls Cq from the curves, a comparison of your mix across platforms reflects the hardware rather than the software; a Cq table keeps the instrument's own Cq. Clarida does not analyze dPCR. If your customers run a format Clarida does not read yet, bring a file to the call.

### How do you tell your mix from the assay?

Carefully, and never per reaction. One run's efficiency could reflect a primer set, an inhibited sample or the mix, and only the last is your reagent. So a field view would work at the population level: across enough labs and assays, the distribution for runs on your mix would be the signal, and their diversity would average out. A question that needs a known quantity is one it could not answer. The sharpest cut would be a controlled one: labs that switch lot or reagent on the same assay, each compared with itself before and after. That would be the field equivalent of the bridging study a QA lab already runs.

### What would you see from your customers' runs?

Nothing, today: no maker receives statistics from labs' runs. What a field view would show, and on what terms, is set down in a pilot before the first statistic.

### Can you see how your mix compares to a competitor's?

No. A pilot looks at your own product only.

### Is this validated for IVD or regulated use?

No. Clarida is for research use: it is not a validated IVD analysis pipeline and is not part of any product's regulatory clearance. It is not for the in-vitro-diagnostic interpretation of a sample. Many master mixes are run for research as well as in regulated workflows; if a customer needs a validated diagnostic pipeline, that is outside what Clarida provides today.

### What can you publish from a pilot?

Nothing yet: there is no field data on your mix. What a pilot produces, and what you may publish, is agreed before it starts.

Updated November 9, 2026

## Bring one master mix and the settings you recommend.

We publish them as a preset your customers start from, then look with you at what a field view should answer. A founder answers within a working day, and the scope and terms are agreed before a pilot starts.

[Plan a pilot](https://clarida.bio/talk-to-us?topic=pilot) · [Talk to a founder](https://clarida.bio/talk-to-us?topic=pilot&channel=write)
