# Take a qPCR experiment from plan to report.

> Clarida takes a qPCR experiment from design to report: plate layout, pipetting guide, run import, Cq calling, normalization, statistics and export.

Source: https://clarida.bio/qpcr
Updated: 2026-11-10

Clarida for qPCR

Clarida is qPCR analysis and workflow software. Bring the run your cycler wrote, or start from the question. Each step hands the next what it recorded, and your data leaves as PDF, Excel and RDML files.

[Start free](https://app.clarida.bio/login) · [Your files in and out](https://clarida.bio/qpcr#qpcr-files)

4 [experiments](https://clarida.bio/pricing#whats-an-experiment) in your first month, then 2 a month. No card.

> **experiments**: The runs and analysis behind one scientific question. Counted once, when you create it. Re-analyzing, reporting and exporting are free, with no limit on samples, assays or runs. [How pricing counts experiments](https://clarida.bio/pricing#whats-an-experiment)

01 How it works

## Six steps, each handing on what it recorded

Start at Define to plan a new experiment, or at Import with a run you already have. Each kind of experiment shows only the parts it uses. The defaults come from co-authors of MIQE, geNorm and qBase, and each is documented in the [methods library](https://clarida.bio/methods).

1. ### [Step 1: Define](https://clarida.bio/qpcr/define)

   Pick a preset, and the experiment opens with the settings set and workflow layout it carries. Clarida and your lab make them, and kit makers can publish theirs. Write down the background and goal, link the papers behind it, and attach your own Excel notebook if you keep one.

   You end with A named experiment with its settings
2. ### [Step 2: Design](https://clarida.bio/qpcr/design)

   Paste samples and assays from a spreadsheet or take them from your library. Choose the mix, and Clarida lays out a 96- or 384-well plate by your lab’s rules, in blocks that suit a multichannel pipette. Then the cycling protocol.

   You end with Plate map, mixes and cycling protocol
3. ### [Step 3: Execute](https://clarida.bio/qpcr/execute)

   At the bench, Clarida lists the amount of every sample, assay and reagent, and each mix with its surplus. Fill the plate by the pipetting guide. A note goes on a well, the run or the experiment.

   You end with A run plate, with your bench notes
4. ### [Step 4: Import](https://clarida.bio/qpcr/import)

   Drop in the run file or a Cq table. Porta can fetch it from the instrument PC instead. A run designed here is matched to your plate, and any conflict is listed for you to settle.

   You end with Curves and Cq, matched to your plate
5. ### [Step 5: Analyze](https://clarida.bio/qpcr/analyze)

   Keep the instrument’s Cq or let Clarida call it from the curves. Every exclusion keeps its reason. Inter-run calibration, efficiency and normalization follow, on reference genes ranked by geNorm and NormFinder, then QC, exploration and statistics.

   You end with Results with the settings behind them
6. ### [Step 6: Report](https://clarida.bio/qpcr/report)

   A PDF or HTML report says which reference genes and tests gave each result, with its tables attached as CSV. The whole experiment goes into your own Excel notebook, and the runs into RDML to publish with a paper. The report and the notebook export both name the settings set.

   You end with A saved report that never changes

Figure 1: Teal marks one sample, well E2, at every step from plan to report. Illustrative data.

02 Experiments

## Six kinds of experiment, each with its answer

Each starts from a preset with only the parts it uses. Five of the six can start from a run you already have.

- ### [Gene expression](https://clarida.bio/qpcr/gene-expression)

  Compare expression between conditions: each target corrected for its own efficiency, normalized on several reference genes or the global mean, and tested, with a fold change and its interval.
  - **Start from**: Relative quantification preset
  - **From a run file**: Yes, analysis only
- ### [Reference genes](https://clarida.bio/qpcr/reference-genes)

  Validate a panel of candidates in one experiment: design it, run it, rank stability by geNorm M and V and by NormFinder, and save the ranking for your next normalizations.
  - **Start from**: Reference gene finder preset
  - **From a run file**: Yes, analysis only
- ### [Present or absent calls](https://clarida.bio/qpcr/detection)

  One call for every sample and target, made only when all replicates agree, with positive, negative and internal controls checked beside it and the cut-offs kept with the saved result.
  - **Start from**: Detection preset
  - **From a run file**: Yes, analysis only
- ### [Genotyping](https://clarida.bio/qpcr/genotyping)

  A genotype table from KASP, TaqMan, DMAS or melt assays: each marker declared once, each call with its quality, and known controls that catch swapped alleles.
  - **Start from**: Genotyping preset
  - **From a run file**: Yes, analysis only
- ### [Plate and instrument QC](https://clarida.bio/qpcr/plate-qc)

  Fill a plate with one sample and one assay, run it, and get a pass or fail, the outliers by position and a heat map.
  - **Start from**: Plate homogeneity check preset
  - **From a run file**: No
- ### [Multi-plate studies](https://clarida.bio/qpcr/multi-plate)

  Several plates as one study: sessions on different days, every run file matched, and each correction shown with its standard error.
  - **Start from**: Relative quantification preset
  - **From a run file**: Yes, analysis only

03 Files in and out

## What goes in, and what comes out

Run files keep their raw curves, so Cq can be called the same way whatever the cycler. Everything you export opens without Clarida.

### In

- **Bio-Rad CFX instruments**: `.pcrd`: plate layout, amplification and melt curves, instrument Cq
- **Roche LightCycler 480**: `.ixo` `.xml`: plate layout with samples, amplification curves; targets, melt curves and the instrument’s Cq when the file holds them, otherwise Clarida calls Cq
- **Thermo Fisher QuantStudio and ViiA 7**: `.eds`: plate layout, amplification and melt curves, instrument Cq; not the older 7500 and 7900HT files
- **QIAGEN Rotor-Gene**: `.rex` `.qrex`: tubes listed by number with their samples, amplification curves, melt curves when run; the file has no Cq, so Clarida calls it
- **RDML**: `.rdml` `.rdm`: whatever the file holds: annotation, curves, Cq
- **A Cq table from any instrument**: `.xlsx` `.csv` `.txt` `.tsv`: a well and a Cq column at least
- **Samples and assays**: Pasted from a spreadsheet, or taken from your library
- **qbase+ archives**: [Imported free](https://clarida.bio/qbase-plus/import), outside your plan’s count, with their exclusions kept

[Porta](https://clarida.bio/methods/connecting-instruments-with-porta), a small Windows program on the instrument PC, shows its export folders inside Clarida.

### Out

- **PDF report**: Its data attached: the report as JSON, each table as CSV, and a README
- **HTML report**: The same report with its data inside; it opens without Clarida
- **Excel**: The whole experiment, written into your own notebook
- **RDML 1.3**: Checked against the schema, to publish the runs with a paper
- **Charts**: Most charts as a PNG, from their toolbar

04 Limits

## What Clarida doesn’t do yet

For research qPCR and RT-qPCR. Where a limit is planned, it says so.

- **Regulated work**: Research use only: not a validated GxP or 21 CFR Part 11 system
- **Digital PCR**: Not yet. A full digital PCR workflow is planned
- **Absolute quantification and copy number**: Not yet. Planned, from a standard curve
- **HRM, ChIP and methylation**: No analysis for them
- **The cycler**: Clarida records the run; it doesn’t start or drive the instrument
- **Word, PowerPoint and share links**: Not available: reports come as PDF, HTML, Excel and RDML

05 Who it’s for

## A page for each kind of lab

What changes for your lab, and what your approver will ask.

- ### [Academic labs](https://clarida.bio/for/academic-labs)

  Analyze your run in the browser; every setting stays with the result.
- ### [Core facilities](https://clarida.bio/for/core-facilities)

  Every group analyzes in a workspace of its own.
- ### [Pharma and biotech R&D](https://clarida.bio/for/pharma-biotech)

  Each experiment starts from your lab’s settings, and its saved report never changes.
- ### [CROs](https://clarida.bio/for/cros)

  Each experiment records which version of the sponsor’s method it started from.

Coming from qbase+? [Bring your archives](https://clarida.bio/qbase-plus/import), free.

Updated October 28, 2026

## Run one experiment through all six steps.

Open a demo experiment, or drop last week’s run in at Import. 4 experiments in your first month, then 2 a month. No card.

[Start free](https://app.clarida.bio/login) · [Talk to a founder](https://clarida.bio/talk-to-us?topic=demo)
