# Concentration converter: DNA copies from ng/µL

> DNA copy number calculator: ng/µL, nM and copies/µL in the sample and the reaction, and copies per partition for dPCR. Free, no account.

Source: https://clarida.bio/tools/concentration-converter
Updated: 2026-10-29

[Free tools](https://clarida.bio/tools)

Enter one amount of your template, as mass, moles or copies, and read the others: in the sample, the reaction and per dPCR partition.

Free, no account

[Open the tool](https://app.clarida.bio/concentration-converter)

- **You start with**: A concentration and your template
- **You end with**: Mass, moles and copies, λ for dPCR

Video: The concentration converter with its default settings, a human template (3.35 pg/copy), 2 µL of sample in a 20 µL reaction and a QX200 with 20,000 partitions: 10 ng/µL is typed into Mass, Sample concentration, and every other field fills in, among them 2.99e+3 copies/µL in the sample, 299 copies/µL in the reaction, 5.97e+3 copies in the reaction and 0.299 copies per partition; Results shows the input, a conversion factor of 299 and the output, 2.99e+3 copies/µL; a click on Copies, Reaction quantity makes it the output, 5.97e+3 copies; then the template is changed to E. coli (0.00497 pg/copy) in the settings, and the copies become 2.01e+6 copies/µL in the sample, 4.02e+6 copies in the reaction and 201 copies per partition. [Watch full size · 0:27](https://clarida.bio/videos/concentration-converter-hero.mp4)

Figure: Type one value and read all the others, in the sample, in the reaction and per partition, for the template you pick.

## How the numbers are worked out

Every conversion goes through the total copies of template in the reaction. Your input is turned into that total, and every other field is worked out from it:

- Sample concentration = copies ÷ sample volume
- Reaction concentration = copies ÷ reaction volume
- Reaction quantity = copies
- Copies per partition = copies ÷ partition count

For mass, each is multiplied by the mass of one copy; for moles, divided by Avogadro’s number, 6.022 × 10²³ per mol. A weight in daltons uses 1 Da = 1.66 × 10⁻¹² pg. The organism presets use 650 Da per base pair; a calculator set to 660, about 1.5% higher, gives copy numbers about 1.5% lower.

**A worked example**, with the defaults: human genomic DNA at 10 ng/µL, 2 µL in a 20 µL reaction, on a 20,000-partition platform. One human genome copy (haploid) is 3.35 pg, so:

- 10 ng/µL × 2 µL = 20 ng in the reaction: 20,000 pg ÷ 3.35 pg = about 5,970 copies.
- The sample holds 5,970 ÷ 2 µL = about 2,990 copies/µL.
- The reaction holds 5,970 ÷ 20 µL = about 299 copies/µL, or 1 ng/µL.
- Per partition: 5,970 ÷ 20,000 = 0.299 copies.

The organism presets, each the mass of one haploid genome copy, with genome sizes rounded:

| Organism | Genome size | Mass per copy |
| --- | --- | --- |
| Human (Homo sapiens) | 3.1 × 10⁹ bp | 3.35 pg |
| Mouse (Mus musculus) | 2.7 × 10⁹ bp | 2.91 pg |
| Rat (Rattus norvegicus) | 2.9 × 10⁹ bp | 3.13 pg |
| Zebrafish (Danio rerio) | 1.4 × 10⁹ bp | 1.51 pg |
| C. elegans | 1.0 × 10⁸ bp | 0.108 pg |
| Drosophila melanogaster | 1.4 × 10⁸ bp | 0.151 pg |
| Arabidopsis thaliana | 1.6 × 10⁸ bp | 0.173 pg |
| Yeast (Saccharomyces cerevisiae) | 1.2 × 10⁷ bp | 0.013 pg |
| E. coli | 4.6 × 10⁶ bp | 0.00497 pg |

The digital PCR presets, nominal partition counts per reaction:

| Maker | Platform | Partitions |
| --- | --- | --- |
| Bio-Rad | QX200 and QX600 | 20,000 |
| Bio-Rad | QX700 | 17,000 |
| Bio-Rad | QX Continuum | 25,000 |
| Qiagen | QIAcuity, 8.5k and 26k nanoplate | 8,500 and 26,000 |
| Thermo Fisher | QuantStudio Absolute Q | 20,000 |
| Stilla | Naica | 17,000 |
| Roche | Digital LightCycler, three plates | 20,000, 28,000, 100,000 |
| Formulatrix | Constellation, 24-well and 96-well | 36,000 and 8,000 |
| JN Medsys | Clarity Plus | 40,000 |

## How it works

01 In the tool: Concentration converter › Conversion matrix

### Type one value, read every other

One table: mass, moles and copies down the side; across, the concentration in the sample and in the reaction, the reaction quantity, and copies per partition. Type in any field and the rest fill in. Click a result to make it your output; double-click it to clear the table and start from it as your input. Scientific notation works (1.5e6), and results keep three significant digits.

- **Mass:** pg/µL to µg/µL, pg/mL to mg/mL, µg/L and mg/L; quantities from ag to mg
- **Moles:** aM to M; quantities from amol to mol
- **Copies:** per µL, mL and L; a quantity in copies
- **Digital PCR:** copies per partition, shown as λ

02 In the tool: Concentration converter › Template

### Tell it what one copy weighs

Pick an organism, or enter a molecular weight. For a plasmid or an amplicon, that is its length in bp × 650 Da: a 3,000 bp plasmid weighs about 1,950 kDa.

- **Default:** human, 3.35 pg per copy
- **Custom weight:** in pg, fg and ag per copy, Da up to TDa, g/mol and kg/mol

03 In the tool: Concentration converter › Platform

### Match your volumes and your instrument

The volumes set the step from sample to reaction; the platform sets the partitions a reaction is split into.

- **Sample volume:** 2 µL by default
- **Reaction volume:** 20 µL by default
- **Platform:** a Bio-Rad QX200 with 20,000 partitions by default, any preset above, or a count of your own

04 In the tool: Concentration converter › Results

### Copy the number you need

Under the table, Results shows your input, the conversion factor and the output, each with a copy button.

## What the converter doesn’t do

- **Take a sequence length**: Not yet: enter the length × 650 Da as a custom weight
- **Find λ from the positive partitions**: Not here: it divides the copies by the partition count, with no Poisson correction, and counts the whole reaction volume as partitioned

## Frequently asked questions

### Is the concentration converter free?

Yes, with no account, and nothing to install.

### How do you convert ng/µL to copies/µL?

Pick your template in the settings, type the ng/µL in the mass row under sample concentration, and read copies/µL in the bottom row. For human genomic DNA, 1 ng holds about 300 genome copies.

### Can it convert µM to ng/mL, or nM to µg/mL?

Yes, for any molecule once you enter its weight: pick Custom weight in the settings and give it in g/mol or Da. Then type the molar concentration in the moles row and read the mass row.

### Why does another copy number calculator give a slightly different number?

One cause is the mass of a base pair: Clarida’s presets use 650 Da per bp, and a calculator using 660 gives about 1.5% fewer copies.

### What do sample volume and reaction volume mean here?

Sample volume is how much of your sample you pipette in; reaction volume is the total in the well. Sample concentration is that of the tube you pipette from, reaction concentration that of the mix it lands in.

### Does the molecular weight change the copy number?

It changes every conversion between mass and copies, and between mass and moles. Conversions between copies and moles, between sample and reaction, and to copies per partition do not depend on it.

## Cite this tool

Interactive on the page: Format: APA, Vancouver, BibTeX; Copy.

Clarida. (2026). Concentration converter (Version 2026.11.0) \[Web application\]. Retrieved November 18, 2026, from https://app.clarida.bio/concentration-converter

Updated October 29, 2026

## Work out the copies going into your next reaction.

Type the concentration you measured, and every other unit fills in.

[Open the tool](https://app.clarida.bio/concentration-converter) · [Talk to a founder](https://clarida.bio/talk-to-us?topic=help)