# RDES validator: check a qPCR raw data table

> Check a qPCR raw data table against RDES v1.0, with the cell and the fix for every error, and download a corrected file. Free, no account.

Source: https://clarida.bio/tools/rdes-validator
Updated: 2026-10-29

[Free tools](https://clarida.bio/tools)

Paste or upload your raw data table and see which cells break RDES v1.0, why, and how to fix each one.

Free, no account

[Open the tool](https://app.clarida.bio/rdes)

- **You start with**: Your data table (TSV or CSV)
- **You end with**: What to fix, and a corrected file

Video: The RDES validator on its melting demo file: the data import is successful but the file is invalid against RDES v1.0, with 1 error in Format, 1 error in Structure and Consistency passed. Format opens on its five checks; the crossed one, decimal notation, opens on Cell G2 (Cq/Tm), which uses a comma, with 87,8 corrected to 87.8. Structure opens on its nine checks; the crossed one, Cq/Tm values, opens on Cell G3, a melting temperature of -5 that must be positive. Then the summary of what was read: melting curve data, 90 rows, 82 temperatures from 60 to 92.4, 5 samples, 5 targets and 1 dye; and the result whole, with the partly corrected file to download. [Watch full size · 0:33](https://clarida.bio/videos/rdes-validator-hero.mp4)

Figure: Every error with its cell, what is wrong and the fix, and the decimal commas already corrected in a file to download.

## What RDES is, and the version it checks

- **The format**: RDES, the Real-time PCR Data Essential Spreadsheet: one tab-separated table with the raw data of one qPCR run, put forward by the HEROIC consortium as a simpler companion to RDML ([Untergasser et al., 2023](https://pubmed.ncbi.nlm.nih.gov/36916500/))
- **Its columns**: Seven fixed ones (Well, Sample, Sample Type, Target, Target Type, Dye, then Cq or Tm); from column 8, the raw fluorescence at each cycle (each temperature for a melt); amplification and melting data in two files
- **The version checked**: RDES v1.0, as in [the specification at rdml.org](https://rdml.org/rdes.html)
- **Who made the validator**: Clarida, not the RDML consortium

## How it works

Drop a `.tsv`, `.csv` or `.txt` file of up to 10 MB; pasting the table from a spreadsheet works too. It is checked in three layers, and it is valid when all three pass.

01 In the tool: RDES validator › Validation details › Format

### Characters a journal’s parser can read

No quotation marks around cells, no tabs inside cells, a dot as the decimal separator, no thousand separators, and UTF-8 text. RDES needs tabs between columns, so save your table as tab-separated text before you share it.

02 In the tool: RDES validator › Validation details › Structure

### Every column and code as the specification spells it

- **Headers:** Well, Sample, Sample Type, Target, Target Type and Dye, in that order and spelled exactly, then Cq or Tm.
- **The header row:** cycle numbers as whole numbers, temperatures as numbers.
- **Wells:** letters and a number (A1, B12, AA1) with as many letters in every well; numbers alone for rotor instruments.
- **Codes:** sample types `unkn`, `ntc`, `nac`, `std`, `ntp`, `nrt`, `pos` and `opt`; target types `toi` and `ref`; case-sensitive.
- **Values:** a Cq that is positive, empty, or -1.0 for a failed reaction; Tm values positive, several joined by semicolons without spaces; fluorescence as numbers.
- **No empty cells** in the six fixed text columns.

03 In the tool: RDES validator › Validation details › Consistency

### Rows that agree with each other

A sample keeps one sample type in every row, and a target keeps one target type and dye. Each combination of well, target and dye appears once, and every row has as many columns as the header.

04 In the tool: RDES validator › Validation details › Download corrected RDES

### Each error with its cell, and a corrected file

Every error shows where your spreadsheet would show it (Cell G2, Cq/Tm column), what is wrong and what to do; a comma decimal comes with its corrected value. A summary says what was read: the kind of data, the rows, the cycles (or temperatures) with their range, the samples, targets and dyes. When comma decimals and thousand separators are the only errors, you download a fixed tab-separated file; otherwise a partly fixed one, with a list of what is left for your source data.

## What the RDES validator doesn’t do

- **Judge your data**: It checks the format, never your curves, Cq values or controls
- **Tell whether a baseline was subtracted**: RDES asks for raw fluorescence; check it in your instrument’s export settings
- **Convert RDES to RDML**: Not yet

## Frequently asked questions

### Is the RDES validator free?

Yes, with no account: open the tool and paste your table.

### Is your table stored?

No. It is sent to Clarida’s server for the check, and nothing is saved there.

### Can you check a comma-separated table?

Yes, the validator reads it, but RDES itself requires tabs. Save the table as tab-separated text before you share it.

### Which version of RDES does it check?

RDES v1.0, with the rules of [the v1.0 specification](https://rdml.org/rdes.html).

### Can you try it without your own data?

Yes. The Help panel has two example files to load, one with amplification data and one with melting data.

## Cite this tool

Interactive on the page: Format: APA, Vancouver, BibTeX; Copy.

Clarida. (2026). RDES validator (Version 2026.11.0) \[Web application\]. Retrieved November 18, 2026, from https://app.clarida.bio/rdes

Updated October 29, 2026

## Check the table before it goes out with your manuscript.

Paste it or drop the file; each error comes back with its cell and its fix.

[Open the tool](https://app.clarida.bio/rdes) · [Talk to a founder](https://clarida.bio/talk-to-us?topic=help)