Skip to content

Free tools

RDES validator: check a qPCR raw data table

Paste or upload your raw data table and see which cells break RDES v1.0, why, and how to fix each one.

You start withYour data table (TSV or CSV)
You end withWhat to fix, and a corrected file
Every error with its cell, what is wrong and the fix, and the decimal commas already corrected in a file to download.
On this page

What RDES is, and the version it checks

The formatRDES, the Real-time PCR Data Essential Spreadsheet: one tab-separated table with the raw data of one qPCR run, put forward by the HEROIC consortium as a simpler companion to RDML (Untergasser et al., 2023)
Its columnsSeven fixed ones (Well, Sample, Sample Type, Target, Target Type, Dye, then Cq or Tm); from column 8, the raw fluorescence at each cycle (each temperature for a melt); amplification and melting data in two files
The version checkedRDES v1.0, as in the specification at rdml.org
Who made the validatorClarida, not the RDML consortium

How it works

Drop a .tsv, .csv or .txt file of up to 10 MB; pasting the table from a spreadsheet works too. It is checked in three layers, and it is valid when all three pass.

01In the tool: RDES validator › Validation details › Format

Characters a journal’s parser can read

No quotation marks around cells, no tabs inside cells, a dot as the decimal separator, no thousand separators, and UTF-8 text. RDES needs tabs between columns, so save your table as tab-separated text before you share it.

02In the tool: RDES validator › Validation details › Structure

Every column and code as the specification spells it

  • Headers: Well, Sample, Sample Type, Target, Target Type and Dye, in that order and spelled exactly, then Cq or Tm.
  • The header row: cycle numbers as whole numbers, temperatures as numbers.
  • Wells: letters and a number (A1, B12, AA1) with as many letters in every well; numbers alone for rotor instruments.
  • Codes: sample types unkn, ntc, nac, std, ntp, nrt, pos and opt; target types toi and ref; case-sensitive.
  • Values: a Cq that is positive, empty, or -1.0 for a failed reaction; Tm values positive, several joined by semicolons without spaces; fluorescence as numbers.
  • No empty cells in the six fixed text columns.

03In the tool: RDES validator › Validation details › Consistency

Rows that agree with each other

A sample keeps one sample type in every row, and a target keeps one target type and dye. Each combination of well, target and dye appears once, and every row has as many columns as the header.

04In the tool: RDES validator › Validation details › Download corrected RDES

Each error with its cell, and a corrected file

Every error shows where your spreadsheet would show it (Cell G2, Cq/Tm column), what is wrong and what to do; a comma decimal comes with its corrected value. A summary says what was read: the kind of data, the rows, the cycles (or temperatures) with their range, the samples, targets and dyes. When comma decimals and thousand separators are the only errors, you download a fixed tab-separated file; otherwise a partly fixed one, with a list of what is left for your source data.

What the RDES validator doesn’t do

Judge your dataIt checks the format, never your curves, Cq values or controls
Tell whether a baseline was subtractedRDES asks for raw fluorescence; check it in your instrument’s export settings
Convert RDES to RDMLNot yet

Frequently asked questions

Is the RDES validator free?

Yes, with no account: open the tool and paste your table.

Is your table stored?

No. It is sent to Clarida’s server for the check, and nothing is saved there.

Can you check a comma-separated table?

Yes, the validator reads it, but RDES itself requires tabs. Save the table as tab-separated text before you share it.

Which version of RDES does it check?

RDES v1.0, with the rules of the v1.0 specification.

Can you try it without your own data?

Yes. The Help panel has two example files to load, one with amplification data and one with melting data.

Cite this tool

Format

Clarida. (2026). RDES validator (Version 2026.11.0) [Web application]. Retrieved November 18, 2026, from https://app.clarida.bio/rdes

Updated

Check the table before it goes out with your manuscript.

Paste it or drop the file; each error comes back with its cell and its fix.

More free tools

All free tools
  • RDML viewer

    Open a run’s curves, plate and Cq values without the instrument software.

    You start with
    An RDML file, version 1.0 to 1.3
    You end with
    Curves, plate and Cq table of the run
  • Plate editor

    Plan each well’s sample and assay, then paste the layout into your instrument software.

    You start with
    Sample and assay names, or a run file
    You end with
    A plate layout to copy or export
  • Concentration converter

    Go between mass, moles and copy numbers.

    You start with
    A concentration and your template
    You end with
    Mass, moles and copies, λ for dPCR