A call per sample and target, made only when the replicates agree

Bring a screening run. Clarida calls each sample present, absent or inconclusive per target, against its own Cq (Ct) cut-off. For research use.

4 in your first month, then 2 a month. No card.

New experimentqPCR start page › Detection
Already ran the plateAnalysis only › Import & review
On this page

What you get

A call table: one row per sample, one column per target, one call in each cell. Above it, three cards answer the questions in order: what was tested (samples × targets), whether the controls passed, and the result, such as “3 of 7 positive”. A Detected column counts the positives in each row. With controls configured, a QC dot on every row and column shows where a failing one points. Hover a cell to see its count, for example 2/3.

Save the analysis and it is kept as a frozen record, with the cut-off each target was called against. Add it to a PDF or HTML file with the Report builder, which carries the call grid and the counts.

stx1stx2eaehlyAS1S2S3?S4S5S3 · eaecut-off 38Rep 1Rep 2Rep 3no Cq303540Inconclusive, 2 of 3stx1stx2eaehlyAS1S2S3?S4S5S3 · eaecut-off 38Rep 1Rep 2Rep 3no Cq303540Inconclusive, 2 of 3
Fig. 1A call for every sample and target, and one cell opened: two replicates fall below the eae cut-off, one gives no Cq, so the call is inconclusive. Illustrative data.

How is a call made?

As a kit insert’s interpretation table states it, for every unknown sample and every target you test.

DetectedEvery included replicate has a Cq below the target’s cut-off
Not detectedNo included replicate has
InconclusiveThe replicates disagree; Clarida does not average its way to a call
Not measuredNothing is left to judge, so a gap never reads as a negative

Where Clarida differs from most kit inserts: a failing control flags the result, and never changes the call.

The internal control (IAC, often called IPC) fails in a sampleThat sample’s row is flagged; its calls stay as computed, and there is no Invalid call
A positive or no-template control failsThe target it implicates is flagged, on its column
The IAC’s acceptable rangeIts kit’s, else the experiment’s positive-control range; with neither, it must amplify

How it works in Clarida

01In the app: Design › Assay Prep

A cut-off for each target, and which ones are controls

Each target carries its own detection cut-off, in Cq. Its type decides whether it becomes a column of the call table or a check on it. A gene of interest or a reference gene gets calls; a control is checked.

  • Detection cutoff (Cq): per target; left empty, the experiment’s default applies
  • Target type: gene of interest by default; the three control types (positive, negative, IAC) are checks

In full on the Design page

02In the app: Import › Import & annotate

Your run in, with every sample’s role

Import the instrument’s file or a Cq table, and each well is matched to its sample and assay. The type you give each sample matters here: only unknowns get a call.

  • Checked, not called: positive, no-template, no-RT and other negative control samples

On the Import page: Import & annotate

03In the app: Analyze › Raw data

Curves to check before you trust a call

When the file brings curves, you see each well’s amplification and melt plot, and choose whose Cq the call uses. A late, noisy curve close to the cut-off is exactly the one worth a look.

  • Cq source: automatic by default, the cycler’s when the file has it, otherwise Clarida’s, for the whole experiment
  • Cq method: a curve fit per well (Clarida’s default), a baseline and threshold, the second-derivative maximum

In full on the Analyze page

04In the app: Analyze › Sample/Assay QC

Controls checked per sample and per target

The internal amplification control is checked in every unknown, so a sample where it failed is flagged. Positive control samples must amplify each target, and negatives must stay clean. The verdicts carry through to the call table.

  • Negative controls: automatic by default, a Cq floor or a ΔCq margin

In full on the Analyze page

05In the app: Analyze › Detection

The call table, recomputed as you work

Detection computes as soon as you open it, and again whenever a Cq, an exclusion, a sample type or a cut-off changes. An excluded well leaves the call, which is then made on the replicates that remain. Save the analysis to freeze it.

  • Detection Cq cut-off: the experiment’s default, empty unless you set it (any Cq counts); shared with Genotype calling

On the Report page: Report builder

Why it is done this way

A cut-off per target, not one for the plate, because where a Cq stops meaning “present” depends on the assay: its efficiency, its background and the purpose of the test. Choosing that value is a validation decision made per assay, often by the kit maker (Caraguel et al., 2011). Clarida applies the value you give it and records it with every saved result.

Replicates are combined by agreement rather than averaged, because near the limit of detection a target present at a few copies amplifies in some reactions and not in others, by chance alone (Forootan et al., 2017). A mean Cq would hide that; an inconclusive call shows it, and asks you to repeat the sample or decide.

A negative means little without proof that the reaction could have worked. An internal control in each sample shows that inhibition or a failed extraction did not cause it (Hoorfar et al., 2004), and no-template wells show that a positive is not contamination. MIQE 2.0 asks for both kinds of control to be reported (Bustin et al., 2025).

What it doesn’t do

A diagnostic testNot in Clarida: calls are for research use, such as screening panels, GMO checks, food and veterinary studies
Overruling a call by handExclude a replicate, or change the target’s cut-off
Finding your cut-off: limit of detection, probitNot in Clarida: you bring the cut-off, often from the kit maker
Calls in the Excel notebook and RDMLIn the PDF and HTML report, as the call grid and counts

Frequently asked questions

Which Ct cut-off is used for a target?

The target’s own detection cut-off first, then the experiment’s default. If neither is set, any Cq counts as detected, which is rarely what a screening run wants.

Does a failing IPC make the call invalid?

No. Clarida has no Invalid call: the sample’s row is flagged and the call stays as computed, for you to judge. A strongly positive sample that suppresses its internal control is flagged like any other failure.

Can a kit bring its own cut-offs?

Yes. A kit can bring its cut-offs into your experiment. To use another value for your run, change the target’s own cut-off: the experiment’s default never overrides it.

Are your controls called too?

No. Only unknown samples get a call, and only on targets of interest and reference genes. Controls appear as QC verdicts beside the table, and in Sample/Assay QC.

Updated

Call your own screening run.

Import a run you already have and read its call table. 4 experiments in your first month, then 2 a month. No card.

Other experiments

All kinds of experiment
  • Gene expression

    Compare expression between conditions: each target corrected for its own efficiency, normalized on several reference genes or the global mean, and tested, with a fold change and its interval.

    Start from
    Relative quantification preset
    From a run file
    Yes, analysis only
  • Reference genes

    Validate a panel of candidates in one experiment: design it, run it, rank stability by geNorm M and V and by NormFinder, and save the ranking for your next normalizations.

    Start from
    Reference gene finder preset
    From a run file
    Yes, analysis only
  • Genotyping

    A genotype table from KASP, TaqMan, DMAS or melt assays: each marker declared once, each call with its quality, and known controls that catch swapped alleles.

    Start from
    Genotyping preset
    From a run file
    Yes, analysis only
  • Plate and instrument QC

    Fill a plate with one sample and one assay, run it, and get a pass or fail, the outliers by position and a heat map.

    Start from
    Plate homogeneity check preset
    From a run file
    No
  • Multi-plate studies

    Several plates as one study: sessions on different days, every run file matched, and each correction shown with its standard error.

    Start from
    Relative quantification preset
    From a run file
    Yes, analysis only