Skip to content

Compared with dedicated qPCR software

qbase+, GenEx and REST 2009: what each does best

qbase+, GenEx and REST 2009 each do the analysis well. Clarida adds the plate before it, and imports your qbase+ workspaces free.

4 in your first month, then 2 a month. No card.

You keepGenEx for PCA and replicate planning
You addPlate layout and mixes, from your lists
On this page

When is qbase+, GenEx or REST better for you?

Each was written by people who know qPCR, and the methods in them are published.

You classify samples on many genesGenEx: PCA, self-organizing maps, clustering and heat maps, with NormFinder beside geNorm
You plan replicates from a pilotGenEx: a nested ANOVA shows how much variance each step adds
Your lab works under GxPMultiD sells GenEx GxP, an edition for regulated labs
You need one quick two-group answerREST 2009: free, with a randomization test that assumes no normal distribution
A qbase+ study must stay unchangedFinish it in the install you have; the workspace imports when you’re ready
You work in R alreadyThe packages there have a comparison of their own

Has your analysis outgrown one computer?

  • The analysis lives on one licensed computer. A colleague waits for it, or does the work again.
  • The plate starts in a spreadsheet. Layout and volumes are typed again into the cycler: none of the three documents a step that does it, as of October 26, 2026.
  • Your study spans several plates. REST 2009 takes one table of Cq values, with no step between runs.
  • A reviewer asks which settings made a figure. The project file sat on a laptop that has since been reassigned.
  • It runs on one operating system. REST 2009 is a Windows program that needs .NET Framework 2.0.

Side by side

What you needqbase+GenExREST 2009Clarida
Design
Planning the replicates
Details
AdviceSample maximization, three inter-run calibrators, a geNorm pilot firstStronger: From a pilotA nested ANOVA shows the variance each step adds, to plan replicatesNot documentedNot in the user guideYou set themReplicates per reaction, by you or a preset
The plate layout
Details
After the runWells named in a run editor; a layout copies to other platesNot documentedNot in the product pagesPer geneCq entered per gene, not per wellStronger: GeneratedBy your lab’s rules, in blocks for a multichannel pipette; the free Plate editor writes a QuantStudio or CFX setup file
Execute
Mixes and pipetting
Details
Not documentedNot in the manualNot documentedNot in the product pagesNot documentedNot in the user guideStronger: Worked outEach mix with its surplus, then a guide to fill the plate
Import
The run comes in
Details
Cq tablesFrom 32 named instruments, plus RDML and two generic formatsText exportsThe text files cyclers exportPastedCq per gene and group, or Rotor-Gene Q resultsRun filesFour makers’ files with their curves, RDML, or a Cq table; checked against your plate
Analyze
Cq from the raw curves
Details
Imports CqNo raw curves in the manualImports CqFrom instrument export filesTyped inCq pasted per geneStronger: Built inA curve fit per well by default, a threshold or the second-derivative maximum; the instrument’s Cq kept
Efficiency
Details
Per targetTyped, or from a dilution series, optionally per run, with its errorBuilt inEfficiency correction in preprocessingPer geneFrom a standard curve, or typed; 100% if left emptyPer targetFrom your dilution series, pooled over runs, with its error
Several reference genes
Details
SeveralEvery marked gene combined; global mean and custom factors tooBuilt inNormalization to selected reference genesSeveralCombined by geometric meanSeveralCombined by geometric mean, or the global mean
Which reference genes are stable
Details
geNormM and V, plus an expert reading of how many genes to useTwo methodsgeNorm and NormFinderNot documentedNot in the user guideTwo methodsgeNorm and NormFinder, side by side in one experiment
Several runs
Details
CalibratorsOne or more per gene, applied after normalization, with its errorBuilt inInterplate calibrationOne tableOne table of Cq values, no step between runsBuilt inA run effect fitted across all runs, with its error
Error carried to the result
Details
Built inReplicates, efficiency, normalization factor and calibrationNot documentedNot in the product pagesIntervalsBootstrap confidence intervals on the ratioBuilt inFrom the replicates and the efficiency through to the normalized result
Statistics
Details
WizardGuides you to a t-test, ANOVA, rank test, correlation or Cox modelStronger: ExtensiveTests with multiple-testing correction, plus PCA, clustering, heat maps and neural networksTwo groupsRandomization test, no normality assumedCommon testst-tests, ANOVA with post-hoc comparisons, rank-based methods and correlation; adjusted p-values
Report
Results out
Details
Tables, RDMLExcel and CSV tables, charts as SVG or PDF, projects in RDMLNot documentedExport not in the product pagesTable, plotsBox plots saved by right-clickReport, Excel, RDMLA PDF or HTML report with each table as CSV; the experiment in your Excel notebook; RDML 1.3
Throughout
The whole lab in one place
Details
Per computerWindows, Mac and Linux; one user per workspacePer userA two-year license key for one userPer computerA Windows programStronger: SharedOne workspace in the browser, with named settings sets the lab shares, on a paid plan
A year later
Details
Your workspaceOn your computer, backed up at each upgrade; Clarida imports itNot documentedNot in the product pagesNot documentedNot in the user guideStronger: FrozenA saved analysis never changes, even after an update; earlier versions of the design and settings can be restored

marks the stronger tool for that need.

In short

Stronger in GenExPlanning the replicates · Statistics
Stronger in ClaridaThe plate layout · Mixes and pipetting · Cq from the raw curves · The whole lab in one place · A year later
A drawThe run comes in · Efficiency · Several reference genes · Which reference genes are stable · Several runs · Error carried to the result · Results out

How do you check it on a reported run?

  • Take a result you have already reported. Import the run behind it, or the whole qbase+ workspace, which comes in free.
  • Match the settings before the numbers. Use the same reference genes, efficiencies and calibrators, then compare the normalized quantities rather than the Cq values.
  • Read a difference before trusting either side. Two causes to rule out first: an efficiency typed in one tool and fitted in the other, and another set of reference genes.

What can you keep running beside it?

Keep in GenExPCA and clustering, on the normalized values in Clarida’s Excel notebook
Keep in REST 2009A quick two-group test, on the notebook’s Cq per well with its sample and target
Bring from qbase+Whole workspaces, imported free, never counted toward your plan
Look at a reaction elsewhereRDML 1.3 with the raw curves, for RDML-Tools once migrated to 1.4; the file carries no analysis settings

Frequently asked questions

Is qbase+ still available?

We found no current download when we checked on October 29, 2026. Bio-Rad’s current CFX Maestro bulletin (August 2026) no longer lists the qbase+ license its earlier one bundled, and the US VA’s technical reference calls version 3.2 the most current it knows. If you have a working install, your workspaces import into Clarida free.

Does Clarida have NormFinder, like GenEx?

Yes. Clarida rates reference gene stability with geNorm and NormFinder, and you can compare the two in one experiment. NormFinder is checked against its authors’ Excel add-in on their published example; geNorm’s M values match qbase+.

Do any of these tools plan the experiment?

GenEx helps decide how many replicates to run at which step, from a pilot. The qbase+ manual advises putting as many samples of a gene as you can in one run, with the same three calibrators on every plate where that is impossible. Laying out a plate or working out a mix is documented for none of the three, as of October 26, 2026. In Clarida you list the samples and assays: it lays out the plate by your lab’s rules, gives every mix with its surplus and guides you through filling the wells. It does not estimate how many replicates you need; GenEx goes further there.

Is Clarida a GxP edition, like GenEx GxP?

No. Clarida has no electronic signatures or sign-off, and MultiD sells GenEx GxP as an edition for regulated labs. Clarida stores each setting change, each automatic exclusion and each accepted QC deviation with who and when. A saved analysis is frozen.

What do these tools cost?

REST 2009 is free. GenEx is licensed per user: Thermo Fisher lists GenEx Professional v7.0 at €1,430 for a two-year key, and MultiD gives no price for GenEx 8. Clarida’s free plan: 4 experiments in your first month, then 2 a month. No card. Imported qbase+ workspaces never count toward it; the pricing page has the paid plans.

Sources

Each source with the day we last checked it. Something out of date? Tell us.

Checked

Rerun a result you have already reported.

Import the run behind your last qbase+, GenEx or REST 2009 figure and set the numbers side by side. qbase+ workspaces come in free. 4 experiments in your first month, then 2 a month. No card.

Other comparisons

All comparisons
  • Spreadsheets

    You keep
    Your own formulas, Prism for figures
    You add
    Plate, mixes and analysis, linked
  • Instrument software

    You keep
    The run, the protocol, signed records
    You add
    The plan, and runs from four makers
  • R and Python scripts

    You keep
    New methods, the wider pipeline
    You add
    The plan, the mixes, published methods
  • ELN or LIMS

    You keep
    Samples, signatures, the release
    You add
    qPCR methods your team doesn’t code
  • Benchling

    You keep
    The record, stock and sign-off
    You add
    The qPCR layout, mixes and method