Methods
Check how Clarida sets up, imports and analyzes a qPCR run.
From presets and plate layouts to run-file import and genotyping: the steps in the app’s own labels, then how each part of Clarida works and why.
All methods11 methods
Plate editor: laying out a qPCR plate by hand
How to place samples and assays by hand, in the free Plate editor or Run Layout’s Manual mode, then check and export the layout.
- Published
- By
- Jan Hellemans
- Reading time
- 20 min read
- Topic
- Samples, assays and plates
Workflow layouts
How to choose which sections an experiment shows, and in what order, and how layouts work: what they hold, the editor's rules, locking.
- Published
- By
- Jan Hellemans
- Reading time
- 16 min read
- Topic
- Presets, settings and layouts
Experiment settings sets
How to derive your lab's settings set from Clarida defaults and change it in use, and how a set inherits and locks its values.
- Published
- By
- Jan Hellemans
- Reading time
- 13 min read
- Topic
- Presets, settings and layouts
Presets: start an experiment already set up
How to start from a preset, build your own and change one in use, and how they work: what they carry, the shelf, and locking.
- Published
- By
- Jan Hellemans
- Reading time
- 11 min read
- Topic
- Presets, settings and layouts
Genotyping by allelic discrimination
How to turn an allelic-discrimination run into a sample-by-marker genotype table, and how Clarida makes each call: method, cut-offs and controls.
- Published
- By
- Jan Hellemans
- Reading time
- 20 min read
- Topic
- Analysis
Decimal comma and point: what Clarida reads
Enter 0.5 or 0,5: Clarida reads one separator as the decimal and always shows a point. A typed 1,234.5 is refused.
- Published
- By
- Jan Hellemans
- Reading time
- 5 min read
- Topic
- Data entry and import
Pasting sample and assay lists from Excel
How samples and assays get into an experiment, and what one pasted table can carry: types, quantities, units, positions, QC limits and custom properties.
- Published
- By
- Jan Hellemans
- Reading time
- 11 min read
- Topic
- Samples, assays and plates
Importing qPCR run files and Cq (Ct) tables
Which run files and Cq (Ct) tables Clarida reads, and why an import takes one step without a design and three with one.
- Published
- By
- Jan Hellemans
- Reading time
- 10 min read
- Topic
- Data entry and import
Connecting instruments with Porta
How to set up Porta on the instrument PC, so its export folders and LightCycler 480 runs open inside Clarida.
- Published
- By
- Jan Hellemans
- Reading time
- 11 min read
- Topic
- Data entry and import
Exploring qPCR data
How Clarida keeps exploring relative quantities apart from statistical tests, and how a view worth keeping becomes an annotated snapshot.
- Published
- By
- Jan Hellemans
- Reading time
- 4 min read
- Topic
- Analysis
Generating a qPCR plate layout
How to let Run Layout lay out a qPCR plate, adjust it with four settings or by hand, and how Auto picks each setting.
- Published
- By
- Jan Hellemans
- Reading time
- 10 min read
- Topic
- Samples, assays and plates
Presets, settings and layouts3 methods
Workflow layouts
How to choose which sections an experiment shows, and in what order, and how layouts work: what they hold, the editor's rules, locking.
- Published
- By
- Jan Hellemans
- Reading time
- 16 min read
Experiment settings sets
How to derive your lab's settings set from Clarida defaults and change it in use, and how a set inherits and locks its values.
- Published
- By
- Jan Hellemans
- Reading time
- 13 min read
Presets: start an experiment already set up
How to start from a preset, build your own and change one in use, and how they work: what they carry, the shelf, and locking.
- Published
- By
- Jan Hellemans
- Reading time
- 11 min read
Samples, assays and plates3 methods
Pasting sample and assay lists from Excel
How samples and assays get into an experiment, and what one pasted table can carry: types, quantities, units, positions, QC limits and custom properties.
- Published
- By
- Jan Hellemans
- Reading time
- 11 min read
Plate editor: laying out a qPCR plate by hand
How to place samples and assays by hand, in the free Plate editor or Run Layout’s Manual mode, then check and export the layout.
- Published
- By
- Jan Hellemans
- Reading time
- 20 min read
Generating a qPCR plate layout
How to let Run Layout lay out a qPCR plate, adjust it with four settings or by hand, and how Auto picks each setting.
- Published
- By
- Jan Hellemans
- Reading time
- 10 min read
Data entry and import3 methods
Importing qPCR run files and Cq (Ct) tables
Which run files and Cq (Ct) tables Clarida reads, and why an import takes one step without a design and three with one.
- Published
- By
- Jan Hellemans
- Reading time
- 10 min read
Connecting instruments with Porta
How to set up Porta on the instrument PC, so its export folders and LightCycler 480 runs open inside Clarida.
- Published
- By
- Jan Hellemans
- Reading time
- 11 min read
Decimal comma and point: what Clarida reads
Enter 0.5 or 0,5: Clarida reads one separator as the decimal and always shows a point. A typed 1,234.5 is refused.
- Published
- By
- Jan Hellemans
- Reading time
- 5 min read
Analysis2 methods
Exploring qPCR data
How Clarida keeps exploring relative quantities apart from statistical tests, and how a view worth keeping becomes an annotated snapshot.
- Published
- By
- Jan Hellemans
- Reading time
- 4 min read
Genotyping by allelic discrimination
How to turn an allelic-discrimination run into a sample-by-marker genotype table, and how Clarida makes each call: method, cut-offs and controls.
- Published
- By
- Jan Hellemans
- Reading time
- 20 min read