When is your cycler’s software enough?
It sets up the protocol, drives the run and calls Cq on the instrument’s own data, which no analysis tool does.
| You need the curves now, at the instrument | The cycler’s software, offline, on the PC beside the run |
|---|---|
| You run one plate on one cycler | With assays you have already validated, its own analysis is enough |
| Your work needs signed records | Bio-Rad’s Security Edition of CFX Maestro, or Thermo Fisher’s SAE module for Design and Analysis: user roles, an audit trail, e-signatures |
| Your lab runs Applied Biosystems cyclers | Diomni Design and Analysis 3 adds CNV, genotyping and multi-plate analysis for those, on Windows or Mac |
| You run regulated work on a Roche cycler | LightCycler PRO: new software, an updated automatic Cq, described as 21 CFR Part 11 compatible |
| Your Rotor-Gene study needs several reference genes | Q-Rex’s Gene Expression Advanced plug-in: several reference genes, a calibrator and real efficiency |
Does your study reach past the instrument PC?
- The plate is planned in a spreadsheet. It is then typed again into the instrument software, and once more into the analysis.
- The lab has two brands of cycler. Each program reads its own maker’s files, so a study that spans both ends up in a spreadsheet.
- Cq values from two cyclers look alike but come from different algorithms. In a published comparison, curve-analysis methods gave different results on the same data, most of all on technical test data (Ruijter 2013).
- Analysis waits for the instrument PC. Or for the one computer with a license: CFX Maestro is sold per license.
- Last year’s project needs reopening. The file sits on a PC that has since been replaced.
Side by side
| What you need | Instrument software | Clarida |
|---|---|---|
| Define | ||
Why you run itDetails | Notes on the runA run carries its notes and an ID in CFX Maestro; the file holds one run | Stronger: Goal and settingsBackground, goal and linked papers, plus a preset that brings the settings set it carries, your lab’s once you save one |
| Design | ||
Laying out the plateDetails | Wizards and importsThe CFX Maestro Setup Wizard places targets and samples in an area you select; Design and Analysis reads a layout from a text or CSV file, and makes plate files for a batch of sample sheets | Stronger: GeneratedFrom your sample and assay lists, by your rules for grouping and fill order, over as many plates as it takes |
Protocol and run setupDetails | Stronger: Built inProtocol, templates and the cycler itself; Design and Analysis applies the method recommended for your master mix | Plate filesThe free Plate editor writes a CFX .pltd file or a QuantStudio setup, layout only; your cycler’s software runs the protocol |
| Execute | ||
Mixes and volumesDetails | A calculatorCFX Maestro’s Master Mix Calculator, per target, with an excess volume | From the plateEach mix counted from the wells it fills, surplus included; fixed once the runs are ready |
Filling the plateDetails | A plate mapPrint the plate and a note per well in CFX Maestro; a fill guide is not documented | Stronger: GuidedOne stage at a time; notes on a well and the run come back when you analyze |
| Import | ||
Runs from other cyclersDetails | Its maker’sEach reads its own brand; Diomni also opens 7500, 7900HT, StepOne and ViiA 7 runs | Stronger: Four makersBio-Rad, Thermo Fisher, QIAGEN and Roche run files, plus RDML, under one method |
| Analyze | ||
Calling CqDetails | The maker’s methodRegression or a single threshold in CFX Maestro; Crt in Design and Analysis; an improved Ct algorithm in Diomni | Your choiceThe instrument’s Cq, kept unchanged, or Clarida’s own curve fit per well, on any cycler |
Efficiency and reference genesDetails | Per target, severalEfficiency per target; several reference genes, rated by geNorm M in CFX Maestro, plotted in Design and Analysis, and in Q-Rex’s Gene Expression Advanced plug-in | Stronger: Pooled, two stability methodsEfficiency pooled over every run, its error carried to the result; geNorm and NormFinder for any cycler |
Plates from several runsDetails | VariesCalibrated per target in a CFX Maestro Gene Study; in Diomni, relative quantification stays one plate at a time (October 29, 2026) | Built inAny sample measured on two runs calibrates them; each run’s correction comes with its error |
| Report | ||
Report and data outDetails | PDF and RDMLCFX Maestro saves its reports as PDF; RDML comes out of it, Design and Analysis and Rotor-Gene Q | Report, Excel, RDMLA PDF or HTML report with methods sentences; the whole experiment in Excel; RDML 1.3 with the raw curves |
| Throughout | ||
Audit trail and e-signaturesDetails | Stronger: AvailableBio-Rad’s Security Edition and Thermo Fisher’s SAE module: user roles, audit trail, e-signatures | PartialEach setting change stored with who and when; earlier versions of the design kept; no e-signatures |
marks the stronger tool for that need.
In short
| Stronger in instrument software | Protocol and run setup · Audit trail and e-signatures |
|---|---|
| Stronger in Clarida | Why you run it · Laying out the plate · Filling the plate · Runs from other cyclers · Efficiency and reference genes |
| A draw | Mixes and volumes · Calling Cq · Plates from several runs · Report and data out |
How do you check it on your next run?
- Export the run as you do now. Drop the native file into Clarida; the instrument’s Cq comes in as written.
- Compare one ratio, both ways. Set the efficiency to 100% and use one reference gene: the fold change should be the one your software reports.
- Then change one thing at a time. Your measured efficiencies first, a second reference gene next, and see what each one moves.
Can you keep your cycler’s software beside it?
| Keep at the instrument | The protocol, the run and its signed records, in the cycler’s software |
|---|---|
| Plan the plate first | The free Plate editor saves a CFX .pltd file or a QuantStudio setup file, with a free account; you add the protocol at the cycler |
| Bring the run to Clarida | The native file, as each maker writes it, or straight from the instrument PC with Porta |
| Put many plates in one study | Runs calibrated on the samples they share |
| What does not go back | The protocol: a run’s plate setup file from Start Run carries the layout, and you add the protocol at the cycler |
Frequently asked questions
Do you still need the instrument software?
Yes. It runs the cycler, and Clarida does not; you also set the protocol there. Clarida plans the experiment beforehand and picks up again from the run file; its free Plate editor writes the layout for a CFX or QuantStudio cycler.
Can you open a pcrd or eds file without the instrument software?
Yes, with a free Clarida account, on any computer. Drop a CFX .pcrd, a QuantStudio or ViiA 7 .eds, a Rotor-Gene .rex or a LightCycler 480 export into an experiment, and the curves come in with the instrument’s Cq. The import method says what each file brings.
Can runs from two cyclers share one experiment?
Yes. Set the Cq source to Calculated, so every run is called by one method, and runs that share samples are calibrated against each other. A Rotor-Gene file holds no Cq, so Clarida always calls it.
Can Clarida stand in for a Security Edition under 21 CFR Part 11?
No. Clarida has no electronic signatures, so a run that must be signed stays in the vendor’s security edition. Clarida stores each setting change, each automatic exclusion and each accepted QC deviation with who and when, keeps imported data unchanged and freezes saved analyses. Even the vendor’s edition is one part of compliance: its user guide says Bio-Rad makes no claim that it is CFR compliant in and of itself.
What does each maker’s software cost?
It differs by maker. Bio-Rad ships CFX instruments without it, “Order CFX Maestro Software separately” (Bulletin 3971, August 2026), with the price behind a login. Thermo Fisher’s downloads need a sign-in and state no price. Roche lets the LightCycler 96 analysis software be loaded free of charge on any PC. QIAGEN lets the Rotor-Gene Q software be copied within the organization that owns the instrument (manual). Clarida’s free plan: 4 experiments in your first month, then 2 a month. No card.
Sources
Each source with the day we last checked it. Something out of date? Tell us.
- Bio-Rad, CFX Maestro user guide, version 2.3Efficiency, reference genes, Gene Study, statistics, Master Mix Calculator, Setup Wizard, PDF reportsChecked October 26, 2026
- Bio-Rad, CFX Maestro Security Edition user guide, version 1.1User roles, electronic signatures, an audit trail; "no claim" of CFR compliance in itselfChecked October 26, 2026
- Bio-Rad, CFX Maestro software (product page)Version 2.4, Windows; multi-plate study analysis across runs; sold per license, price after loginChecked November 10, 2026
- Bio-Rad, CFX Maestro Software, Bulletin 3971 (August 2026)Instruments ship without it: "Order CFX Maestro Software separately"Checked October 29, 2026
- Bio-Rad, BioRadiations: reference gene selection in CFX MaestroCFX Maestro rates reference gene stability with geNorm’s M valueChecked October 26, 2026
- Thermo Fisher, QuantStudio Design and Analysis 2 user guide (v2.8, October 2025)Templates, plate setup imports, the SAE module, Crt, RDML export, Windows and macOSChecked October 26, 2026
- Thermo Fisher, Relative Quantification module user guide (Design and Analysis 2)Several endogenous controls, efficiency per target, ΔΔCt or a relative standard curveChecked October 26, 2026
- Thermo Fisher, Diomni Design and Analysis Software 3 (RUO)Adds CNV, genotyping and analysis across plates; relative quantification one at a time; Windows or MacChecked October 29, 2026
- Thermo Fisher, QuantStudio 6 and 7 Pro software downloadsDownloads need a thermofisher.com sign-in; no price statedChecked October 29, 2026
- Roche, LightCycler 480 operator’s manual, software 1.5 (hosted by Le Bonheur)Several reference genes, efficiency from standard curves, a traceable database with an audit trailChecked October 26, 2026
- Roche Spain, instruments: LightCycler 96LightCycler 96: relative and absolute quantification, melt, genotyping; analysis software free on any PCChecked November 10, 2026
- Roche, LightCycler PRO system (2024)New software with an updated automatic Cq; "Compatibility with 21 CFR Part 11"Checked November 10, 2026
- QIAGEN, Rotor-Gene Q MDx user manual (February 2022)RDML export, an audit trail in the run file; copied freely within the owning organizationChecked October 26, 2026
- QIAGEN, Q-Rex softwareThe Gene Expression Advanced plug-in: several reference genes, a calibrator, real efficiencyChecked October 29, 2026
- Ruijter et al. (2013), Evaluation of qPCR curve analysis methods, Methods 59:32Curve-analysis methods differed considerably on technical data, less on biomarker dataChecked October 26, 2026