Compared with instrument software

The plan before your run, the study after it

Your cycler’s software drives the plate. Clarida plans it beforehand, then reads the run file on any computer, beside runs from other makers.

4 in your first month, then 2 a month. No card.

You keepThe run, the protocol, signed records
You addThe plan, and runs from four makers
On this page

When is your cycler’s software enough?

It sets up the protocol, drives the run and calls Cq on the instrument’s own data, which no analysis tool does.

You need the curves now, at the instrumentThe cycler’s software, offline, on the PC beside the run
You run one plate on one cyclerWith assays you have already validated, its own analysis is enough
Your work needs signed recordsBio-Rad’s Security Edition of CFX Maestro, or Thermo Fisher’s SAE module for Design and Analysis: user roles, an audit trail, e-signatures
Your lab runs Applied Biosystems cyclersDiomni Design and Analysis 3 adds CNV, genotyping and multi-plate analysis for those, on Windows or Mac
You run regulated work on a Roche cyclerLightCycler PRO: new software, an updated automatic Cq, described as 21 CFR Part 11 compatible
Your Rotor-Gene study needs several reference genesQ-Rex’s Gene Expression Advanced plug-in: several reference genes, a calibrator and real efficiency

Does your study reach past the instrument PC?

  • The plate is planned in a spreadsheet. It is then typed again into the instrument software, and once more into the analysis.
  • The lab has two brands of cycler. Each program reads its own maker’s files, so a study that spans both ends up in a spreadsheet.
  • Cq values from two cyclers look alike but come from different algorithms. In a published comparison, curve-analysis methods gave different results on the same data, most of all on technical test data (Ruijter 2013).
  • Analysis waits for the instrument PC. Or for the one computer with a license: CFX Maestro is sold per license.
  • Last year’s project needs reopening. The file sits on a PC that has since been replaced.

Side by side

What you needInstrument softwareClarida
Define
Why you run it
Details
Notes on the runA run carries its notes and an ID in CFX Maestro; the file holds one runStronger: Goal and settingsBackground, goal and linked papers, plus a preset that brings the settings set it carries, your lab’s once you save one
Design
Laying out the plate
Details
Wizards and importsThe CFX Maestro Setup Wizard places targets and samples in an area you select; Design and Analysis reads a layout from a text or CSV file, and makes plate files for a batch of sample sheetsStronger: GeneratedFrom your sample and assay lists, by your rules for grouping and fill order, over as many plates as it takes
Protocol and run setup
Details
Stronger: Built inProtocol, templates and the cycler itself; Design and Analysis applies the method recommended for your master mixPlate filesThe free Plate editor writes a CFX .pltd file or a QuantStudio setup, layout only; your cycler’s software runs the protocol
Execute
Mixes and volumes
Details
A calculatorCFX Maestro’s Master Mix Calculator, per target, with an excess volumeFrom the plateEach mix counted from the wells it fills, surplus included; fixed once the runs are ready
Filling the plate
Details
A plate mapPrint the plate and a note per well in CFX Maestro; a fill guide is not documentedStronger: GuidedOne stage at a time; notes on a well and the run come back when you analyze
Import
Runs from other cyclers
Details
Its maker’sEach reads its own brand; Diomni also opens 7500, 7900HT, StepOne and ViiA 7 runsStronger: Four makersBio-Rad, Thermo Fisher, QIAGEN and Roche run files, plus RDML, under one method
Analyze
Calling Cq
Details
The maker’s methodRegression or a single threshold in CFX Maestro; Crt in Design and Analysis; an improved Ct algorithm in DiomniYour choiceThe instrument’s Cq, kept unchanged, or Clarida’s own curve fit per well, on any cycler
Efficiency and reference genes
Details
Per target, severalEfficiency per target; several reference genes, rated by geNorm M in CFX Maestro, plotted in Design and Analysis, and in Q-Rex’s Gene Expression Advanced plug-inStronger: Pooled, two stability methodsEfficiency pooled over every run, its error carried to the result; geNorm and NormFinder for any cycler
Plates from several runs
Details
VariesCalibrated per target in a CFX Maestro Gene Study; in Diomni, relative quantification stays one plate at a time (October 29, 2026)Built inAny sample measured on two runs calibrates them; each run’s correction comes with its error
Report
Report and data out
Details
PDF and RDMLCFX Maestro saves its reports as PDF; RDML comes out of it, Design and Analysis and Rotor-Gene QReport, Excel, RDMLA PDF or HTML report with methods sentences; the whole experiment in Excel; RDML 1.3 with the raw curves
Throughout
Audit trail and e-signatures
Details
Stronger: AvailableBio-Rad’s Security Edition and Thermo Fisher’s SAE module: user roles, audit trail, e-signaturesPartialEach setting change stored with who and when; earlier versions of the design kept; no e-signatures

marks the stronger tool for that need.

In short

Stronger in instrument softwareProtocol and run setup · Audit trail and e-signatures
Stronger in ClaridaWhy you run it · Laying out the plate · Filling the plate · Runs from other cyclers · Efficiency and reference genes
A drawMixes and volumes · Calling Cq · Plates from several runs · Report and data out

How do you check it on your next run?

  • Export the run as you do now. Drop the native file into Clarida; the instrument’s Cq comes in as written.
  • Compare one ratio, both ways. Set the efficiency to 100% and use one reference gene: the fold change should be the one your software reports.
  • Then change one thing at a time. Your measured efficiencies first, a second reference gene next, and see what each one moves.

Can you keep your cycler’s software beside it?

Keep at the instrumentThe protocol, the run and its signed records, in the cycler’s software
Plan the plate firstThe free Plate editor saves a CFX .pltd file or a QuantStudio setup file, with a free account; you add the protocol at the cycler
Bring the run to ClaridaThe native file, as each maker writes it, or straight from the instrument PC with Porta
Put many plates in one studyRuns calibrated on the samples they share
What does not go backThe protocol: a run’s plate setup file from Start Run carries the layout, and you add the protocol at the cycler

Frequently asked questions

Do you still need the instrument software?

Yes. It runs the cycler, and Clarida does not; you also set the protocol there. Clarida plans the experiment beforehand and picks up again from the run file; its free Plate editor writes the layout for a CFX or QuantStudio cycler.

Can you open a pcrd or eds file without the instrument software?

Yes, with a free Clarida account, on any computer. Drop a CFX .pcrd, a QuantStudio or ViiA 7 .eds, a Rotor-Gene .rex or a LightCycler 480 export into an experiment, and the curves come in with the instrument’s Cq. The import method says what each file brings.

Can runs from two cyclers share one experiment?

Yes. Set the Cq source to Calculated, so every run is called by one method, and runs that share samples are calibrated against each other. A Rotor-Gene file holds no Cq, so Clarida always calls it.

Can Clarida stand in for a Security Edition under 21 CFR Part 11?

No. Clarida has no electronic signatures, so a run that must be signed stays in the vendor’s security edition. Clarida stores each setting change, each automatic exclusion and each accepted QC deviation with who and when, keeps imported data unchanged and freezes saved analyses. Even the vendor’s edition is one part of compliance: its user guide says Bio-Rad makes no claim that it is CFR compliant in and of itself.

What does each maker’s software cost?

It differs by maker. Bio-Rad ships CFX instruments without it, “Order CFX Maestro Software separately” (Bulletin 3971, August 2026), with the price behind a login. Thermo Fisher’s downloads need a sign-in and state no price. Roche lets the LightCycler 96 analysis software be loaded free of charge on any PC. QIAGEN lets the Rotor-Gene Q software be copied within the organization that owns the instrument (manual). Clarida’s free plan: 4 experiments in your first month, then 2 a month. No card.

Sources

Each source with the day we last checked it. Something out of date? Tell us.

Checked

The Cq stays the one your cycler wrote.

Drop a CFX, QuantStudio or LightCycler 480 file into Clarida. It uses the instrument’s Cq by default, beside the normalized result. 4 experiments in your first month, then 2 a month. No card.

Other comparisons

All comparisons
  • Spreadsheets

    You keep
    Your own formulas, Prism for figures
    You add
    Plate, mixes and analysis, linked
  • Dedicated qPCR software

    You keep
    GenEx for PCA and replicate planning
    You add
    Plate layout and mixes, from your lists
  • R and Python scripts

    You keep
    New methods, the wider pipeline
    You add
    The plan, the mixes, published methods
  • ELN or LIMS

    You keep
    Samples, signatures, the release
    You add
    qPCR methods your team doesn’t code
  • Benchling

    You keep
    The record, stock and sign-off
    You add
    The qPCR layout, mixes and method