Skip to content

Built by the people behind MIQE, geNorm and qbase+

qPCR results you can defend.

Drop in the run file your cycler made. Clarida checks every step from raw curves to statistics, and keeps each setting with the result.

4 in your first month, then 2 a month. No card. Export to Excel or RDML at any time.

152025303540Cycle6.5×LPSControl20253035Cycle6.5×LPSControl
Fig. 1IL6 after LPS: its curves rise earlier, and the gap, corrected for efficiency and two reference genes, is the fold change. Illustrative data.

Reads the run files of

CFX · LightCycler 480 · QuantStudio · Rotor-GeneAll file formats

New in November 2026

The report builder, Run layout on the plate, and NormFinder beside geNorm.Read the release notes

01Who built it

You’ve probably cited their work already.

Jan Hellemans led the qBase paper, Jo Vandesompele geNorm’s, and both co-authored MIQE. Clarida builds on their work, and the open methods library explains its steps.

Building qPCR analysis software since 2007.How Clarida started

Citation counts: OpenAlex, November 15, 2026.

02The problem

Analyze the same run twice by hand, and you can get two answers.

Cq values move by hand from instrument software to spreadsheet, statistics and figure. Each step can lose a well or swap a reference gene, and change the answer.

One of these slips, at its worst:

“Interpreting reported Cq values, assuming a 100% efficient PCR, may lead to assumed gene expression ratios that are 100‑fold off.”
Ruiz-Villalba et al., Life 2021
124816IL6 fold change, LPS vs control (log scale)As planned6.5×GAPDH alone as reference13.1×Efficiency assumed to be 28.2×One replicate left out4.6×A Cq from the wrong column1.4×124816IL6 fold change (log)As planned6.5×GAPDH alone as reference13.1×Efficiency assumed to be 28.2×One replicate left out4.6×A Cq from the wrong column1.4×
Fig. 2One run, analyzed five ways. Each slip on its own moves the answer, from 1.4× to 13×. Illustrative data.

03How it works

One record, from question to report.

Work through an experiment in the order you already run it. Each step builds on what the last one recorded, so nothing is retyped or lost.

One record

One experiment holds it all: the question, plate layout, mixes, notes from the bench, raw curves and Cq values, excluded wells, analysis settings and result. No well goes missing on the way, and every saved report names the settings and reference genes it used.

  1. Step 1: Define

    Write down the question, its background and goal, and link the papers behind it. Start from a preset or a blank experiment.

  2. Step 2: Design

    Paste samples and assays or pick them from your library. Click one well: the plate is laid out the way your lab pipettes and checked for a missing control.

  3. Step 3: Execute

    At the bench you see how much to collect and what goes into every mix. Fill the plate step by step, noting anything unusual on the well itself.

  4. Step 4: Import

    Add your run file or its Cq export. Porta, our instrument connector, can fetch the file from the cycler’s PC instead, no USB stick needed. It arrives matched to the plate you designed.

  5. Step 5: Analyze

    Keep the instrument’s Cq values or let Clarida call them. Replicates, efficiency and reference genes are checked before normalization. The t-tests and ANOVA report the fold change with its interval, not only a p-value.

  6. Step 6: Report

    Export a PDF report with each table as CSV, the whole experiment to your own Excel notebook, or RDML to publish the runs with a paper. Your data is never locked in.

Fig. 3Teal marks one sample, well E2, at every step from plan to report. Illustrative data.

See the full workflow

Two ways in.

Planning a new experiment? Start at Define, and what you set up there carries through to the result. Already have a run from your instrument? Start at Import and analyze straight away.

Only the steps you need.

A genotyping run doesn't need everything a gene expression study does. Each kind of experiment opens with only the steps it uses, and your lab can hide, group and reorder them to fit how it works. Hiding one changes what you see, never the result.

How workflow layouts work

04Experiments

The answer your experiment asks for.

Fold changes, stability rankings, present or absent calls, genotypes, plate maps and calibrated studies, each checked the way that kind of experiment needs.

Applications
no change0.5124816Fold change, LPS vs control (log scale)IL66.5× 95% CI 4.8 to 8.9IL1BTNFCCL2no change124816Fold change vs control (log)IL66.5× 95% CI 4.8 to 8.9IL1BTNFCCL2
geNormNormFinderHPRT1HPRT1YWHAZYWHAZSDHASDHAGAPDHGAPDHACTBACTBB2MB2MdisagreeV2/3 = 0.11, below 0.15: two genes are enoughgeNormNormFinderHPRT1HPRT1YWHAZYWHAZSDHASDHAGAPDHGAPDHACTBACTBB2MB2MdisagreeV2/3 = 0.11, below 0.15:two genes are enough
stx1stx2eaehlyAS1S2S3?S4S5S3 · eaecut-off 38Rep 1Rep 2Rep 3no Cq303540Inconclusive, 2 of 3stx1stx2eaehlyAS1S2S3?S4S5S3 · eaecut-off 38Rep 1Rep 2Rep 3no Cq303540Inconclusive, 2 of 3
G/GG/CC/CSample 1G/GSample 2G/CSample 3C/CSample 4InconclusiveNTCNo amplification−4−1.51.54ΔCqG/GG/CC/CSample 1G/GSample 2G/CSample 3C/CSample 4InconclusiveNTCNo amplification−4−1.51.54ΔCq
AH112Outer ring+0.3 cycles19% lower quantityAH112Outer ring +0.3 cycles
As measured: shift per runRun 1Run 2Run 3Run 4ACTB−0.21+0.38−0.05−0.12HPRT1−0.25+0.41−0.02−0.14IL6−0.44+0.43+0.06−0.05MYC−0.18+0.29−0.11noneCalibrated: what is leftRun 1Run 2Run 3Run 4±0.04±0.04±0.05±0.05±0.05±0.05±0.06±0.06±0.03±0.03±0.07±0.07±0.05±0.05±0.06noneShift, 0 to 0.4+ cyclesShift removed, ± its standard errorMYC, run 4: no shared sample, not calibratedAs measured: shift per runRun 1Run 2Run 3Run 4ACTB−0.21+0.38−0.05−0.12HPRT1−0.25+0.41−0.02−0.14IL6−0.44+0.43+0.06−0.05MYC−0.18+0.29−0.11noneCalibrated: what is leftACTB±0.04±0.04±0.05±0.05HPRT1±0.05±0.05±0.06±0.06IL6±0.03±0.03±0.07±0.07MYC±0.05±0.05±0.06noneMYC, run 4: not calibrated
Fig. 4a3aFold change after LPS for four targets, each with its 95% confidence interval, n = 3 per group: none of the intervals touches no change. Illustrative data.Fig. 4b3bThe same six candidates ranked by geNorm and by NormFinder: both put HPRT1 and YWHAZ first, and the one place they differ is flagged. Illustrative data.Fig. 4c3cA call for every sample and target, and one cell opened: two replicates fall below the eae cut-off, one gives no Cq, so the call is inconclusive. Illustrative data.Fig. 4d3dFive samples, each placed on the ΔCq scale with the cut-offs you set: the band it lands in is its call, between bands it is inconclusive, and the no-template control did not amplify. Illustrative data.Fig. 4e3eA 96-well test plate shaded by Cq: the second ring runs 0.1 cycles later than the center, the outer ring 0.3 and the corners 0.9. The four corners are the only wells more than 0.5 cycles from the plate median. Illustrative data.Fig. 4f3fAs measured, run 2 reads late for every target, IL6 by 0.87 cycles against the first. Calibrated, each cell keeps only its standard error; MYC on run 4 shares no sample, so it is marked, not corrected. Illustrative data.

05Reproducibility

Try new settings without touching last year’s results.

Your lab’s analysis choices live in a named settings set that your experiments can start from. Compare a change side by side before the lab adopts it.

  • A set in use is locked: changes become new versions
  • Clarida’s own updates reach your set only after you review them
  • Reports name the set and version each experiment started from
Our qPCR standard
Settingv1 · in usev2 · proposed
Cq methodv1From the raw curvesv2From the raw curves
Replicate Cq SD, exclude abovev10.30v20.25 (changed)
Efficiencyv1Assisted, experiment firstv2Assisted, experiment first
NTC, flag if Cq belowv135v238 (changed)
Normalizationv1Reference genes, geNorm M below 0.5v2Reference genes, geNorm M below 0.5
IL6 experiment, started from v1
Fig. 54Version 1 in use and version 2 proposed, the two changed values marked. Illustrative data.

06Alternatives

See how Clarida compares with what you use now.

Each page says where your current tool works well, and where Clarida differs. Every fact about it is dated and links to its source.

07Pricing

What would your lab pay?

WhoTypical usePrice
Someone who runs qPCR now and then4 experiments in your first month, then 2 a monthFreeno card, no end date
A group with regular qPCR runsAbout 8 experiments a monthAbout €120 a monthpay as you go at €15, in packs of 20
A team where qPCR is core work50 to 100 experiments a month€4,800 to €9,600 a yearLab plan at €8 per experiment

Academic prices shown. On the annual Lab plan, companies pay from €33 per experiment

Priced per experiment, never per seat: the whole team shares one workspace at no cost for each extra person.

See all plans

What counts as one experiment

The runs and analysis behind one scientific question. Counted once, when you create it. Re-analyzing, reporting and exporting are free, with no limit on samples, assays or runs.

08Free tools

Free tools for the work around a run.

The jobs you’d otherwise do in a spreadsheet, or skip. Open one in your browser, add your data and get the answer: no account, nothing to install.

09For manufacturers

For the makers behind every qPCR run.

Your product decides how a run should be read: which targets, which controls, which cut-offs. Clarida publishes that as a preset your customers start from.

Plan a pilot
From the IFUStart from the kit
Controlsto look up and type inPositive, NTC
Targets and dyesto look up and type inFluA FAM · FluB HEX · RSV Cy5 · IC ROX
Cut-offsto look up and type inCq 36 · 36 · 37 · 35
Mixto look up and type in10 µL master mix + 5 µL sample
Cyclingto look up and type in45 cycles, 95/60 °C
Cq method and baselineto look up and type inThe kit’s settings, locked
Dug out and retyped, slips included.All set, from the kit maker
Fig. 65Everything the IFU asks a lab to set up, already in place when it starts from the kit. Illustrative data.

10Roadmap

What Clarida does today, and what's next.

“Today” means in the app now. What comes next has no date yet: the release notes tell you when it arrives.

In Clarida today

  • InstrumentsRun files with their raw curves from CFX, LightCycler 480, QuantStudio and Rotor-Gene, plus RDML; a Cq table from any other instrument
  • ExperimentsGene expression, reference genes, present or absent calls, genotyping, plate and instrument QC and multi-plate studies
  • AnalysisCq called from the raw curves, next to the instrument’s; each assay’s own efficiency; inter-run calibration; normalization against the global mean or reference genes ranked with geNorm and NormFinder
  • Quality controlEvery exclusion with its reason; replicate spread against your threshold; samples, assays and controls checked before normalization
  • Statisticst-tests, ANOVA with post-hoc comparisons, rank-based alternatives and correlation, with Benjamini–Hochberg, Holm or Bonferroni adjustment; the fold change with its confidence interval
  • Your data outA PDF report, your own Excel workbook and RDML
  • RecordsVersioned settings sets and presets, saved with every experiment; tests and explorations kept exactly as run

In development

  • LOD and LOQ calculator
  • ΔΔCq fold-change calculator
  • Primer designer
  • Primer checker
  • Multiplex panel checker
  • Tm calculator
  • Melt curve predictor

Planned

  • Absolute quantification from a standard curve
  • A full digital PCR workflow

Updated with every monthly release.Release notes

Try it on a run you’ve already analyzed.

Drop in the file, put Clarida’s result next to yours, and see every setting behind the difference.

4 experiments in your first month, then 2 a month. No card.