Built by the people behind MIQE, geNorm and qbase+
qPCR results you can defend.
Drop in the run file your cycler made. Clarida checks every step from raw curves to statistics, and keeps each setting with the result.
4 experimentsThe runs and analysis behind one scientific question. Counted once, when you create it. Re-analyzing, reporting and exporting are free, with no limit on samples, assays or runs. How pricing counts experiments in your first month, then 2 a month. No card. Export to Excel or RDML at any time.
Reads the run files of
CFX · LightCycler 480 · QuantStudio · Rotor-GeneAll file formats
New in November 2026
The report builder, Run layout on the plate, and NormFinder beside geNorm.Read the release notes
01Who built it
You’ve probably cited their work already.
Jan Hellemans led the qBase paper, Jo Vandesompele geNorm’s, and both co-authored MIQE. Clarida builds on their work, and the open methods library explains its steps.
Building qPCR analysis software since 2007.How Clarida started
qBase
Relative quantities corrected for efficiency, across reference genes and runs
4,159citations161 in 2026
geNorm
Which reference genes are stable, and how many you need
20,429citations680 in 2026
16,875citations1,465 in 2026
Citation counts: OpenAlex, November 15, 2026.
02The problem
Analyze the same run twice by hand, and you can get two answers.
Cq values move by hand from instrument software to spreadsheet, statistics and figure. Each step can lose a well or swap a reference gene, and change the answer.
One of these slips, at its worst:
“Interpreting reported Cq values, assuming a 100% efficient PCR, may lead to assumed gene expression ratios that are 100‑fold off.”
03How it works
One record, from question to report.
Work through an experiment in the order you already run it. Each step builds on what the last one recorded, so nothing is retyped or lost.
One record
One experiment holds it all: the question, plate layout, mixes, notes from the bench, raw curves and Cq values, excluded wells, analysis settings and result. No well goes missing on the way, and every saved report names the settings and reference genes it used.
Step 1: Define
Write down the question, its background and goal, and link the papers behind it. Start from a preset or a blank experiment.
Step 2: Design
Paste samples and assays or pick them from your library. Click one well: the plate is laid out the way your lab pipettes and checked for a missing control.
Step 3: Execute
At the bench you see how much to collect and what goes into every mix. Fill the plate step by step, noting anything unusual on the well itself.
Step 4: Import
Add your run file or its Cq export. Porta, our instrument connector, can fetch the file from the cycler’s PC instead, no USB stick needed. It arrives matched to the plate you designed.
Step 5: Analyze
Keep the instrument’s Cq values or let Clarida call them. Replicates, efficiency and reference genes are checked before normalization. The t-tests and ANOVA report the fold change with its interval, not only a p-value.
Step 6: Report
Export a PDF report with each table as CSV, the whole experiment to your own Excel notebook, or RDML to publish the runs with a paper. Your data is never locked in.
Fig. 3Teal marks one sample, well E2, at every step from plan to report. Illustrative data.
See the full workflowTwo ways in.
Planning a new experiment? Start at Define, and what you set up there carries through to the result. Already have a run from your instrument? Start at Import and analyze straight away.
Only the steps you need.
A genotyping run doesn't need everything a gene expression study does. Each kind of experiment opens with only the steps it uses, and your lab can hide, group and reorder them to fit how it works. Hiding one changes what you see, never the result.
How workflow layouts work04Experiments
The answer your experiment asks for.
Fold changes, stability rankings, present or absent calls, genotypes, plate maps and calibrated studies, each checked the way that kind of experiment needs.
05Reproducibility
Try new settings without touching last year’s results.
Your lab’s analysis choices live in a named settings set that your experiments can start from. Compare a change side by side before the lab adopts it.
- A set in use is locked: changes become new versions
- Clarida’s own updates reach your set only after you review them
- Reports name the set and version each experiment started from
06Alternatives
See how Clarida compares with what you use now.
Each page says where your current tool works well, and where Clarida differs. Every fact about it is dated and links to its source.
- SpreadsheetsPlanning and math in Excel
- Instrument softwareWhat came with your cycler
- Dedicated qPCR softwareThe tools built for qPCR, side by side
- R and Python scriptsYour own analysis code
- ELN or LIMSWhere your lab keeps its records
- BenchlingIf your lab already runs on it
Coming from qbase+?
Bring one experiment or your whole workspace into Clarida, free and outside your quota. You don’t need it installed.
Your qbase+ work in ClaridaFor your kind of lab
07Pricing
What would your lab pay?
Academic prices shown. On the annual Lab plan, companies pay from €33 per experiment
Priced per experiment, never per seat: the whole team shares one workspace at no cost for each extra person.
See all plansWhat counts as one experiment
The runs and analysis behind one scientific question. Counted once, when you create it. Re-analyzing, reporting and exporting are free, with no limit on samples, assays or runs.
08Free tools
Free tools for the work around a run.
The jobs you’d otherwise do in a spreadsheet, or skip. Open one in your browser, add your data and get the answer: no account, nothing to install.
- Plate editorPlan each well’s sample and assay, then paste the layout into your instrument software.
- Concentration converterGo between mass, moles and copy numbers.
- Excel workbooksTemplates for the qPCR lab, and a tidy-up for your own.
- geNorm reference gene finderRank candidate reference genes by stability, and see how many you need.
- NormFinder reference gene finderRank candidate reference genes with your sample groups taken into account.
- Plate homogeneityTest whether every well on your instrument reads the same.
- RDML viewerOpen a run’s curves, plate and Cq values without the instrument software.
- RDES validatorSee which cells of your data table break the format before you submit.
09For manufacturers
For the makers behind every qPCR run.
Your product decides how a run should be read: which targets, which controls, which cut-offs. Clarida publishes that as a preset your customers start from.
- Kit makersLabs start from your kit’s settings
- Master mix makersLabs start from your cycling and settings
- Instrument makersFrom your run files to statistics
| From the IFU | Start from the kit |
|---|---|
| Controlsto look up and type in | Positive, NTC |
| Targets and dyesto look up and type in | FluA FAM · FluB HEX · RSV Cy5 · IC ROX |
| Cut-offsto look up and type in | Cq 36 · 36 · 37 · 35 |
| Mixto look up and type in | 10 µL master mix + 5 µL sample |
| Cyclingto look up and type in | 45 cycles, 95/60 °C |
| Cq method and baselineto look up and type in | The kit’s settings, locked |
| Dug out and retyped, slips included. | All set, from the kit maker |
10Roadmap
What Clarida does today, and what's next.
“Today” means in the app now. What comes next has no date yet: the release notes tell you when it arrives.
In Clarida today
- InstrumentsRun files with their raw curves from CFX, LightCycler 480, QuantStudio and Rotor-Gene, plus RDML; a Cq table from any other instrument
- ExperimentsGene expression, reference genes, present or absent calls, genotyping, plate and instrument QC and multi-plate studies
- AnalysisCq called from the raw curves, next to the instrument’s; each assay’s own efficiency; inter-run calibration; normalization against the global mean or reference genes ranked with geNorm and NormFinder
- Quality controlEvery exclusion with its reason; replicate spread against your threshold; samples, assays and controls checked before normalization
- Statisticst-tests, ANOVA with post-hoc comparisons, rank-based alternatives and correlation, with Benjamini–Hochberg, Holm or Bonferroni adjustment; the fold change with its confidence interval
- Your data outA PDF report, your own Excel workbook and RDML
- RecordsVersioned settings sets and presets, saved with every experiment; tests and explorations kept exactly as run
In development
- LOD and LOQ calculator
- ΔΔCq fold-change calculator
- Primer designer
- Primer checker
- Multiplex panel checker
- Tm calculator
- Melt curve predictor
Planned
- Absolute quantification from a standard curve
- A full digital PCR workflow
Updated with every monthly release.Release notes
Try it on a run you’ve already analyzed.
Drop in the file, put Clarida’s result next to yours, and see every setting behind the difference.
4 experiments in your first month, then 2 a month. No card.